Main Functions
SiBE041012_B
34
Function and Control
1.12 Inverter POWERFUL Operation
Outline
In order to exploit the cooling and heating capacity to full extent, operate the air conditioner by
increasing the indoor fan rotating speed and the compressor frequency.
Detail
When the [POWERFUL] button is pressed, the fan speed and target temperature are converted
to the following states for 20 minutes.
A
= 50 rpm
Ex: POWERFUL operation in cooling
1.13 Multi-Colored Indicator Lamp / TIMER Lamp
Features
Current operation mode is displayed in color of the lamp of the indoor unit. Operating status can
be monitored even in automatic operation in accordance with the actual operation mode.
The lamp color changes according to the operation.
∗
AUTO ........................................................Red / Blue
∗
DRY ..........................................................Green
∗
COOL........................................................Blue
∗
HEAT ........................................................Red
∗
FAN...........................................................White
∗
TIMER.......................................................Orange
Operation mode
Fan speed
Target temperature
COOL H
tap
+
A
rpm
18°C
DRY
Dry rotating speed +
A
rpm
Lowered by 2.5°C
HEAT
H tap +
A
rpm
31°C
FAN
H tap +
A
rpm
—
AUTO
Same as cooling / heating in
POWERFUL operation
The target temperature is
kept unchanged.
(R13571)
Target temp.
Fan
A
rpm
18˚C
H tap
Set tap
20 minutes
It should be the lower limit of
cooling temperature.
It counts 20 minutes. also
in the remote controller.
POWERFUL
ON
POWERFUL
OFF
Ending condition: "or" in 1 to 3
1. After the lapse of 20 minutes.
2. Operation OFF
3. POWERFUL operation is OFF.
(R15294)
Multi-colored indicator lamp /
TIMER lamp