SiBE041012_B
Service Check Function
Service Diagnosis
67
5. Diagnose by the sound.
beep : The left-side number does not correspond with the error code.
two consecutive beeps : The left-side number corresponds with the error code but the
right-side number does not.
long beep : Both the left-side and right-side numbers correspond with the error code.
(The numbers indicated when you hear the long beep are the error code.
→
Refer to page 68.)
6. Press the [Mode] button.
The right-side number blinks.
7. Press the [Temp] or
button
and change the number until you hear the long beep.
8. Diagnose by the sound.
beep : The left-side number does not correspond with the error code.
two consecutive beeps : The left-side number corresponds with the error code but the
right-side number does not.
long beep : Both the left-side and right-side numbers correspond with the error code.
9. Determine the error code.
The numbers indicated when you hear the long beep are the error code.
Error codes and description
→
Refer to page 68.
10.Press the [Mode] button for 5 seconds to exit from the service check mode.
(When the remote controller is left untouched for 60 seconds, it returns to the normal mode
also.)
(R11672)
(R11673)
(R11671)
(R11672)