Troubleshooting
SiBE041012_B
68
Service Diagnosis
4. Troubleshooting
4.1
Error Codes and Description
: Displayed only when system-down occurs.
Error Codes
Description
Reference
Page
System
00
Normal
—
U0
Refrigerant shortage
75
U2
Low-voltage detection or over-voltage detection
78
U4
Signal transmission error (between indoor unit and outdoor unit)
80
UA
Unspecified voltage (between indoor unit and outdoor unit)
83
Indoor
Unit
A1
Indoor unit PCB abnormality
69
A5
Freeze-up protection control or heating peak-cut control
70
A6
Fan motor (DC motor) or related abnormality
71
C4
Indoor heat exchanger thermistor or related abnormality
73
C7
Front panel open / close fault
74
C9
Room temperature thermistor or related abnormality
73
Outdoor
Unit
E1
Outdoor unit PCB abnormality
84
E5
OL activation (compressor overload)
86
E6
Compressor lock
88
E7
DC fan lock
89
E8
Input overcurrent detection
90
EA
Four way valve abnormality
91
F3
Discharge pipe temperature control
93
F6
High pressure control in cooling
94
H0
Compressor system sensor abnormality
95
H6
Position sensor abnormality
97
H8
DC voltage / current sensor abnormality (25/35 class only)
100
CT or related abnormality (RXG50K2V1B only)
101
H9
Outdoor temperature thermistor or related abnormality
103
J3
Discharge pipe thermistor or related abnormality
103
J6
Outdoor heat exchanger thermistor or related abnormality
103
L3
Electrical box temperature rise
105
L4
Radiation fin temperature rise
106
L5
Output overcurrent detection
108
P4
Radiation fin thermistor or related abnormality
103
U7
Signal transmission error on outdoor unit PCB
(RXG50K2V1B only)
82