Page 1: ...technical data FTXG EV1BW_FTXG EV1BS Wall Mounted Inverter Controlled Unit air conditioning systems Split Sky Air ...

Page 2: ..._FTXG EV1BS 1 Features 2 2 Specifications 3 For indoor units only 3 Technical Specifications 3 Electrical Specifications 4 3 Dimensional drawing centre of gravity 5 Dimensional drawing 5 Centre of gravity 6 4 Piping diagram 7 5 Wiring diagram 8 Wiring diagram 8 6 Sound data 9 Sound pressure spectrum 9 ...

Page 3: ...ng by activating the comfort mode The new titanium apatite photocatalytic air purification filter increases the active surface area for effective purification and deodorisation Horizontal and vertical auto swing 3D air flow ensure efficient air and temperature distribution Powerful mode can be selected for rapid cooling or heating The movement sensor saves power consumption in unoccupied rooms Ind...

Page 4: ...ing High m min 7 7 7 7 8 1 8 1 Medium m min 6 1 6 1 6 5 6 5 Low m min 4 7 4 7 4 9 4 9 Silent Operation m min 3 8 3 8 4 1 4 1 Heating High m min 9 0 9 0 9 6 9 6 Medium m min 7 9 7 9 8 2 8 2 Low m min 6 7 6 7 6 7 6 7 Silent Operation m min 5 4 5 4 5 9 5 9 Fan Motor Quantity 1 1 1 1 Model KFD 280 40 8B Number of steps 5 steps silent and auto Motor Speed cooling High rpm 1400 1400 1470 1470 Medium rpm...

Page 5: ...filter Quantity 2 2 2 2 Item Indoor unit fixing screws Quantity 1 1 1 1 Item Mounting plate Quantity 1 1 1 1 Notes Sound values are measured in an anechoic room Sound pressure level is a relative value depending on the distance and acoustic environment For more details please refer to sound level drawings of this chapter The sound power level is an absolute value indicating the power which a sound...

Page 6: ...ce for performance Space for operation Liquid pipe 6 4CuT The length of pipe outside the unit about 390 Gas pipe 9 5Cut The length of pipe outside the unit about 340 Drain hose connecting part I D J 14 0 O D J 18 0 The hose length on the outside of the unit is approx 440 Wall hole for embedded piping J65 hole Wall hole J65 hole Standard locations of wall holes Cooling Up down automatic Dry Intelli...

Page 7: ... Indoor Units R 410A FTXG EV1BW_FTXG EV1BS 3 Split Sky Air Indoor Units 6 3 Dimensional drawing centre of gravity 3 2 Centre of gravity 4D050964 FTXG25 35E ...

Page 8: ...Units 7 Indoor Units R 410A FTXG EV1BW_FTXG EV1BS 4 Piping diagram 4D045301B FTXG25 35E Indoor unit Heat exchanger Cross flow fan Fan motor Field piping Field piping Refrigerant flow Thermistor on heat exchanger Cooling Heating ...

Page 9: ... H4P Pilot lamp M1F Fan motor M1S M2S M3S Swing motor PCB1 PCB2 PCB3 Printed circuit board R1T R2T Thermistor S1 S51 Connector S1W Operation switch S2W Panel limit switch X1M Terminal strip E1 Earth terminal shield plate E2 Earth terminal heat ex Signal receiver CAUTION Note that operation will restart automatically if the main power supply is turned off and then back on again Intelligent eye sens...

Page 10: ...hearing for continuous noise Legend 50 60Hz 220 240 220 230V H 50 60Hz 220 240 220 230V L NOTE 1 Operation noise differs with operation and ambient conditions 3D050971 FTXG35E Cooling Octave band sound pressure level dB 0dB 0 0002 µ bar approximate threshold hearing for continuous noise Octave band center frequency Hz Legend 50 60Hz 220 240 220 230V H 50 60Hz 220 240 220 230V L NOTE 1 Operation no...

Page 11: ......

Page 12: ...in Belgium by Lannoo The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N V Daikin Europe N V has compiled the content of this publication to the best of its knowledge No express or implied warranty is given for the completeness accuracy reliability or fitness for particular purpose of its content and the products and services...