In heating
The airflow direction will change to spread the air along the floor.
The unit detects the room and floor temperature and
automatically selects 1 of the 3 airflow directions.
Warming up
Downward direc
-
tion
Vertical airflow
direction
Vertical airflow direction sends air directly downward, so if there
is a curtain rail or other object below the air conditioner that
obstructs the flow of air, in some cases it may not be sufficiently
effective.
INFORMATION
If you want to deactivate the Vertical airflow function (e.g. in
case there is furniture or another object under the unit), refer
to “To turn ON/OFF Vertical airflow function” on page 9. If the
Vertical airflow function is deactivated, the airflow will be set
to downward direction.
INFORMATION
Powerful and Comfort airflow operation CANNOT be used at
the same time. The last selected function takes priority.
If the Vertical automatic swing is selected, Comfort airflow
operation will be cancelled.
To turn ON/OFF Vertical airflow function
1.
Press
for at least 2 seconds.
Result:
The menu appears on the display.
2.
Press
or
to change the menu screen.
Result:
The menu appears on the display.
3.
Press
to change the setting.
4.
Press
or
to change the setting.
…is blinking
Vertical airflow function is…
turned ON
turned OFF
5.
To confirm the selected setting press
.
Note:
The display automatically returns to the default screen
after 60 seconds. To return to the default screen sooner, press
twice.
Intelligent eye operation
The system detects movement in the room and automatically
adjusts the airflow direction and temperature in order to avoid
direct contact with people. If no movement is detected for 20
minutes, the system switches to energy saving operation:
Operation
Energy saving operation
Heating
Temperature is lowered by 2°C.
Cooling and drying
If the temperature in the room is:
•
≤30°C, the temperature is raised by 2°C
•
>30°C, the temperature is raised by 1°C
Fan only
Decreases airflow rate.
About Intelligent eye sensor
NOTICE
•
Do NOT hit or push the Intelligent eye sensor. Doing so may
lead to malfunction.
•
Do NOT place large objects near the Intelligent eye sensor.
•
Detection range.
Up to 9 m.
If the installation height is 180cm or less, the distance at which
detection is possible will become shorter.
•
Detection sensitivity.
Changes according to location, the
number of persons in the room, temperature range, etc.
•
Detection mistakes.
Sensor may mistakenly detect pets,
sunlight, moving curtains, etc.
To start/stop Comfort and Intelligent eye operation
1.
Press
one or more times.
Result:
The setting will change as follows:
Display
Operation
Comfort airflow
Intelligent eye
+
Comfort airflow and Intelligent eye
—
Both deactivated
Note:
If there are people close to the front of the indoor unit or
there are too many people, use both operations at the same time.
2.
To stop operation, press
until both symbols
disappear from the LCD.
9
01_EN_3P705032-1.indd 9
30/08/2022 10:19:58 am