1.19 Other Functions
1.19.1 Hot-Start Function
In order to prevent the cold air blast that normally occurs when heating operation is started, the
temperature of the indoor heat exchanger is detected, and the airflow is either stopped or
significantly weakened resulting in comfortable heating.
The cold air blast is prevented using similar control when defrost control starts or when the
thermostat is turned ON.
1.19.2 Signal Receiving Sign
When the indoor unit receives a signal from the remote controller, the unit emits a signal receiving
sound.
1.19.3 Indoor Unit ON/OFF Switch
ON/OFF
switch is provided on the display of the unit.
Press
ON/OFF
switch once to start operation. Press once again to stop it.
ON/OFF
switch is useful when the remote controller is missing or the battery has run out.
The operation mode refers to the following table.
Forced cooling operation
Forced cooling operation can be started by pressing
ON/OFF
switch for 5 ~ 9 seconds while the
unit is not operating.
Refer to page 149 for details.
Forced cooling operation is not started if
ON/OFF
switch is pressed for 10 seconds or more.
1.19.4 Auto-restart Function
If a power failure (even a momentary one) occurs during the operation, the system restarts
automatically in the same conditions as before when the power supply is restored to the conditions
prior to the power failure.
It takes 3 minutes to restart the operation because 3-minute standby function is activated.
Operation mode
Temperature setting
Airflow rate
AUTO
25°C (77°F)
Automatic
R4003799
ON/OFF
switch
Summary of Contents for FTXM-V Series
Page 16: ...SiUS042113E 12 Part 2 Specifications 1 Specifications 13 Part 2 Specifications...
Page 96: ...Troubleshooting SiUS042113E 92 Part 6 Service Diagnosis Reference Check No 01 Refer to P 134...
Page 150: ...Check SiUS042113E 146 Part 6 Service Diagnosis 18 24 class R24539 DC DC W V U...
Page 166: ...Piping Diagrams SiUS042113E 162 Part 8 Appendix RXM24VVJU 3D132217...
Page 171: ...SiUS042113E Operation Limit Part 8 Appendix 167 3 Operation Limit RXM09 12 18 24VVJU 3D133582A...