SiUS042113E
Forced Cooling Operation
Part 7 Trial Operation and Field Settings
149
2. Forced Cooling Operation
Outline
The forced cooling operation is allowed when both the following conditions are met.
1. The outdoor unit is not abnormal and not in the 3-minute standby mode.
2. The outdoor unit is not operating.
Protection functions have priority over all other functions during forced cooling operation.
Details
With indoor unit ON/OFF switch
Press indoor unit
ON/OFF
switch for at least 5 seconds. The operation will start.
Forced cooling operation will stop automatically after about 15 minutes.
To stop the operation, press indoor unit
ON/OFF
switch.
R4003799
With the indoor unit's remote controller
1. Press
Mode
button and select the cooling operation.
2. Press
On/Off
button to turn on the system.
3. Press
Temp
,
buttons and
Mode
button at the same time.
4. Press
Temp
,
buttons, select "
T
", and press
Mode
button for confirmation.
Forced cooling operation will stop automatically after about 30 minutes.
To stop the operation, press
On/Off
button.
R7000227
ON/OFF
switch
1, 3, 4
3, 4
2
4
Summary of Contents for FTXM-V Series
Page 16: ...SiUS042113E 12 Part 2 Specifications 1 Specifications 13 Part 2 Specifications...
Page 96: ...Troubleshooting SiUS042113E 92 Part 6 Service Diagnosis Reference Check No 01 Refer to P 134...
Page 150: ...Check SiUS042113E 146 Part 6 Service Diagnosis 18 24 class R24539 DC DC W V U...
Page 166: ...Piping Diagrams SiUS042113E 162 Part 8 Appendix RXM24VVJU 3D132217...
Page 171: ...SiUS042113E Operation Limit Part 8 Appendix 167 3 Operation Limit RXM09 12 18 24VVJU 3D133582A...