9

English

Indoor Unit Installation

4-4. Wall embedded piping. 

Follow the instructions given under 

.

1) Insert the drain hose to this depth so it won’t be 

pulled out of the drain pipe.

WARNING

Do not bundle the power code with a binding band, a twist tie or other method. 
This may cause heat, electric shock or fire.

5.

Humidifying hose installation work.

5-1. Connecting to the indoor unit. 

• Connect the cuff side of the humidifying hose to the indoor unit duct.

CAUTION

Use caution not to deform the cuff while installing the humidifying hose.

5-2. Connecting the cut humidifying hoses.

• When install the cut humidifying hoses, follow the instructions below.

• Use not more than two elbows to ensure humidifying capacity. 

Inner wall

Vinyl chloride 
drain pipe 
(VP-30)

Drain hose

50mm 
or more

Outer wall

Insert drain hose 
to this depth so 
it won’t be pulled 
out of drain pipe.

Left-side, left-back, or left-bottom piping

Insert as far as possible 
so that there are no gaps.

Cut the cuff 
at this part.

• Left-back piping

It is easier to connect the hose 
with the front grille removed.

Cuff

Humidifying 
hose

Connect the 
cuff side of the 
humidifying 
hose to the 
indoor unit duct.

The protrusion of the 
humidifying hose from the 
wall hole is about 100mm.

(If it is too long, cut the humidifying hose 
and bond the separately sold cuff with 
adhesive for vinyl to adjust the length.)

Pulling out the 
humidifying hose in a 
downward direction.

Pulling out the 
humidifying hose in a 
sideward direction.

Approx. 100mm

Apply the binding band 
at 10mm from the rim 
of the joint to prevent 
the humidifying hose 
from coming off.

Insert each humidifying 
hose to the rim of the joint 
so that there are no gaps.

Apply the binding band at 10mm 
from the rim of the elbow to 
prevent the humidifying hose 
from coming off.

Insert each humidifying 
hose to the rim of the elbow 
so that there are no gaps.

Elbow

Joint

01_EN_3P177302-1.fm  Page 9  Tuesday, May 30, 2006  9:36 AM

Summary of Contents for FTXR28EV1B

Page 1: ...ies Montaj kýlavuzlarý R410A Split serisi Installationsanleitung Split Baureihe R410A Manuel d installation Série split R410A Montagehandleiding R410A Split systeem Manual de instalación Serie Split R410A Manuale d installazione Serie Multiambienti R410A Εγχειρßδιο εγκατÜστασηò διαιροýìενηò σειρÜò R410A Manual de Instalação Série split R410A Рóêоводство по монтажó Серия R410A с раздельной óстановê...

Page 2: ...n TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TCF 015 74736 KRQ EMC97 4957 Daikin TC...

Page 3: ...e cables so that they do not put undue force on the electrical covers or panels Install covers over the wires Incomplete cover installation may cause terminal overheating electrical shock or fire If any refrigerant has leaked out during the installation work ventilate the room The refrigerant produces a toxic gas if exposed to flames After all installation is complete check to make sure that no re...

Page 4: ...tallation work When embedding humidifying hose 1 Cannot be installed to the existing embedded piping Embedding work is separately necessary The length of the humidifying hose is marked on the hose packing material 1 Use an extension hose sold separately when extending the humidifying hose 2 The length of the humidifying hose needs to be set to ensure humidifying capacity Cut off any excess hose Us...

Page 5: ... to the humidifying hose as much as possible If it is difficult to lay the humidifying hose cut it lay it and connect it using the joint or elbow included with the outdoor unit Cut thermal insulation pipe to an appropriate length and wrap it with tape making sure that no gap is left in the insulation pipe s cut line 30mm or more from ceiling 50mm or more from walls on both sides Screws Field suppl...

Page 6: ... on both sides of the front panel 2 Removing and installing the upper panel Removal method 1 Remove the front panel and air filter 2 Hold and pull forward 2 tabs on both sides to discharge them discharge the center tab and then lift up the upper panel Installation method 1 Push in the upper panel along the guide on the top of the front grille and insert the 3 tabs into the slots on the front grill...

Page 7: ...e left air filter to its original position and close the front panel 5 Installing the titanium apatite photocatalytic air purifying filter and deodorizing filter for streamer 1 Open the front panel to pull out the air filter 2 Attach the titanium apatite photocatalytic air purifying filter 3 Attach the deodorizing filter for streamer 4 Replace the air filter to its original position and close the ...

Page 8: ... wireless remote controllers can be set for different addresses 1 Remove the front grille 3 screws 2 Cut the address jumper JA See Fig 1 3 Remove the remote controller lid and cut the address jumper J4 See Fig 2 Attachment on the right side factory default Drain hose Attachment on the left side The drain hose is on the back of the unit Front side of unit Drain hose Drain hose attachment position R...

Page 9: ...the inter unit wiring from the back of the indoor unit to the front It is easier to pull out if bending up the wire edge in advance 3 To connect the inter unit wiring after hooking the unit onto the mounting plate connect the inter unit wiring as shown in the figure at right A A A Bolt size M10 165 285 145 45 14 5 305 44 5 260 5 44 5 37 150 100 385 385 170 302 5 343 5 343 5 393 5 15 890 12 120 120...

Page 10: ...4 Connect the pipes If it is difficult to do remove the front panel first 5 Wrap the insulation on the piping with insulation tape If you are not replacing the drain hose store it in the location shown below 4 3 Left back piping Drain hose Gas pipe Liquid pipe Inter unit wiring Humidifying hose Insulation tape Piping bundle diagram Cut out the piping through hole Install with a downward slope Cut ...

Page 11: ...be pulled out of drain pipe Left side left back or left bottom piping Insert as far as possible so that there are no gaps Cut the cuff at this part Left back piping It is easier to connect the hose with the front grille removed Cuff Humidifying hose Connect the cuff side of the humidifying hose to the indoor unit duct The protrusion of the humidifying hose from the wall hole is about 100mm If it i...

Page 12: ...stem 1 Remove the front grille 3 screws 2 Remove the decelerator assembly parts 1 screw 2 1 Remove the decelerator assembly part screws See Fig 1 2 2 Remove the decelerator assembly part connector Remove by pressing on the tabs on the bottom of the connector See the tab position diagram 1 3 Remove the electric parts box 1 screw 2 tabs 3 1 Remove the electric parts box fixing screw 3 2 Pull the ele...

Page 13: ...to the drain hose attached to the indoor unit as with embedded piping work use any commercially available drain socket nominal diameter 13mm as a joint 9 Improving installation strength We recommend screwing the indoor unit onto a mounting plate in order to improve the installation strength 1 Remove the front grille 2 Screw in the indoor unit with fixing screws 3 Attach the front grille Tab 3 Elec...

Page 14: ...Default is no setting 4 Press SELECT button to set the humidifying hose length Pressing SELECT button changes the hose length You may set the hose length to 5 levels 3M 3 1 4M 4 1 6M 6 1 8M 8 1 10M 5 Press CLOCK button after selecting the hose length Direct the remote controller toward the main unit while operating it 6 Hold CLOCK button for more than 5 seconds The humidifying hose length setting ...

Page 15: ...or larger 2 2 Selection of copper and heat insulation materials When using commercial copper pipes and fittings observe the following 1 Insulation material Polyethylene foam Heat transfer rate 0 041 to 0 052W mK 0 035 to 0 045 kcal mh C Refrigerant gas pipe s surface temperature reaches 110 C max Choose heat insulation materials that will withstand this temperature 2 Be sure to insulate both the g...

Page 16: ...the air supply filter Noise water leakage Did you install the deodorizing filter for the streamer and the titanium apatite photocatalytic air purifying filter Noise water leakage Have you performed a gas leak test Incomplete cooling heating function No refrigerant gas leaks Incomplete cooling heating function Refrigerant gas and liquid pipes and indoor drain hose extension are thermally insulated ...

Page 17: ... 0605 HT 3P177302 1 M05B200 ...

Reviews: