Electrical Box / PCBs
Si041411E
10
Removal Procedure
5
Remove the screw and
slightly draw out the
electrical box.
6
Release the harnesses
from the 3 hooks.
7
Disconnect the
connectors [S41] [S44]
[S46] and release the
harnesses from the
hook.
[S41]: swing motors, humidity
sensor PCB for
humidifying
[S44]: brush motor, filter motors,
limit switch for brush
[S46]: signal receiver / display
PCB
8
Remove the 2 screws.
Step
Procedure
Points
Electrical box
(R19837)
(R19838)
Hook
Hook
Hook
[S46]
[S44]
[S41]
(R19839)
(R19840)