background image

• Indoor Units • R-410A • FUQ-BVV1B

1

10

• Split Sky Air • Indoor Units

17

10

Air flow pattern

4D014054

D

FUQ100B

Heating - air velocity distribution

4-way discharge, air flow direction: down

FUQ100B

Heating - air temperature distribution

4-way discharge, air flow direction: down

Summary of Contents for FUQ71BVV1B

Page 1: ...d Drain up pump with 500mm lift fitted as standard Extremely quiet in operation Easy to install Daikin remote controls give you easy control at your fingertips The wired remote control provides you wi...

Page 2: ...Cross fin coil Multi louver fins and N hix tubes Fan Type Turbo fan Quantity 1 1 1 Air Flow Rate Cooling High m min 19 0 29 0 32 0 Low m min 14 0 21 0 23 0 Heating High m min 19 0 29 0 32 0 Low m min...

Page 3: ...1 1 1 Item Drain hose Clamp metal Insulation for fitting Sealing pad Clamps Screws Washer Joint Holding plate 2 3 ELECTRICAL SPECIFICATIONS FUQ71BVV1B FUQ100BVV1B FUQ125BVV1B Power Supply Name V1 Phas...

Page 4: ...4 Indoor Units R 410A FUQ BVV1B 3 Safety device settings FUQ71 100 125B Model Safety devices FUQ71BUV1B FUQ100BUV1B FUQ125BUV1B FUQ B Fuse Fan motor thermal fuse C Fan motor thermal protector C Off 13...

Page 5: ...ol Wired type BRC1D528 Infrared type Heat pump BRC7CA528W Cooling only BRC7CA529W Central remote control DCS302CA51 Unified ON OFF control DCS301BA51 Schedule timer DST301BA51 Wiring adapter for elect...

Page 6: ...3 1 5 Split Sky Air Indoor Units 6 Indoor Units R 410A FUQ BVV1B 5 Control systems 3TW23651 2 6 5 x 9 Round end slit Cover open Cover closed 5 x 7 Round end slit HoleJ5 5 x 10 Round end slit BRC1D52...

Page 7: ...ion for rear piping Drain connection location for upper piping z Drain pipe can be raised up to 350mm from the top surface of the product Brand name plate note 2 FUQ100 125B 1 Liquid pipe connection J...

Page 8: ...Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipe Indoor heat exchanger Field piping JA C1220T 0 FUQ71 100 125B Field piping JB C1220T 0 Refrigerant p...

Page 9: ...itor green H3P Light emitting diode service monitor red H4P Light emitting diode service monitor orange SS1 Selector switch main sub SS2 Selector switch wireless address set Connector for optional par...

Page 10: ...nal codes 3 Use copper conductors only 4 See wiring diagrams for details 5 Install fuse and mainswitch for safety 6 All field wiring and components must be provided by a licensed electrician 7 The uni...

Page 11: ...und data 9 1 Sound level data Location of microphone Model Sound pressure level Sound power level 230V 50Hz Cooling H L Heating H L Measuring location Cooling H L Heating H L FUQ71B 40 35 40 35 56 51...

Page 12: ...d sound pressure level Octave band center frequency Hz FUQ100B approximate threshold hearing for continuous noise NOTES 1 Sound pressure levels are measured in an anechoic room 2 Operation sound level...

Page 13: ...Split Sky Air Indoor Units 13 10 Air flow pattern 4D028396C FUQ71B Cooling air velocity distribution 4 way discharge air flow direction horizontal FUQ71B Cooling air temperature distribution 4 way dis...

Page 14: ...ndoor Units R 410A FUQ BVV1B 10 Air flow pattern 4D028397C FUQ100B Cooling air velocity distribution 4 way discharge air flow direction horizontal FUQ100B Cooling air temperature distribution 4 way di...

Page 15: ...plit Sky Air Indoor Units 15 10 Air flow pattern 4D028398C FUQ125B Cooling air velocity distribution 4 way discharge air flow direction horizontal FUQ125B Cooling air temperature distribution 4 way di...

Page 16: ...ts 16 Indoor Units R 410A FUQ BVV1B 10 Air flow pattern 4D013863D FUQ71B Heating air velocity distribution 4 way discharge air flow direction down FUQ71B Heating air temperature distribution 4 way dis...

Page 17: ...1 10 Split Sky Air Indoor Units 17 10 Air flow pattern 4D014054D FUQ100B Heating air velocity distribution 4 way discharge air flow direction down FUQ100B Heating air temperature distribution 4 way di...

Page 18: ...s 18 Indoor Units R 410A FUQ BVV1B 10 Air flow pattern 4D014055D FUQ125B Heating air velocity distribution 4 way discharge air flow direction down FUQ125B Heating air temperature distribution 4 way di...

Page 19: ...ote control j d Inlet air j e Discharged air j f Air outlet j g Air flow flap at air outlet j h Refrigerant piping connection electric wire j i Drain pipe j j Air inlet The built in air filter removes...

Reviews: