Indoor Unit Installation
Shaping the refrigerant pipe
4.
Form the shape of the refrigerant pipe in accordance with the restric-
•
tions shown in the illustration.
Protect the open end of the pipe against dust and moisture.
•
Wall
If no flare cap is
available, cover
the flare mouth
with tape to keep
dirt or water out.
Rain
Be sure to
place a cap.
Piping pull-out dimensions
Floor
Wall
Gas pipe
Liquid pipe
Bottom edge of the unit
Centre of the
wall hole
These dimensions are for reference. Please adjust them according to
the conditions at the installation site.
36.5
65
45
70-120
: 320
320
105
45
70-120
Wall
Refrigerant pipe
Left piping
Right piping
Floor
(unit: mm)
Left bottom
piping
Right bottom
piping
Left back
piping
Right back
piping
CAUTION
Min. allowable length
The suggested shortest pipe length is 2.5m, in order to avoid noise from the outdoor unit and vibration.
•
(Mechanical noise and vibration may occur depending on how the unit is installed and the environment in which it is used.)
See the installation manual for the outdoor unit for the maximum pipe length.
•
For multi-connections, see the installation manual for the multi-outdoor unit.
•