background image

3

 

 CAUTION

Do not block the air inlets nor outlets. Impaired air

fl

 ow may result in insuf

fi

 cient performance or trouble.

• 

Do not sit on the outdoor unit, put things on the unit, or pull the unit. Doing so may cause accidents, such as falling or 

• 

toppling down, thus resulting in injury, product malfunctioning, or product damage.
Do not place objects that are susceptible to moisture directly beneath the indoor or outdoor units. Under certain 

• 

conditions, condensation on the main unit or refrigerant pipes, air 

fi

 lter dirt or drain blockage may cause dripping, 

resulting in fouling or failure of the object concerned.
After prolonged use, check the unit stand and its mounts for damage. If they are left in a damaged condition, the unit 

• 

may fall and cause injury.
To avoid injury, do not touch the air inlet or aluminium 

fi

 ns of the indoor or outdoor units.

• 

The appliance is not intended for use by unattended young children or in

fi

 rm persons. Impairment of bodily functions 

• 

and harm to health may result.
Children should be supervised to ensure that they do not play with the unit or its remote controller. Accidental 

• 

operation by a child may result in impairment of bodily functions and harm health.
Avoid impacts to the indoor and outdoor units, or otherwise product damage may result.

• 

Do not place 

fl

 ammable items, such as spray cans, within 1m of the air outlet.

• 

The spray cans may explode as a result of hot air from the indoor or outdoor units.
Be careful not to let pets urinate on the air conditioner. Urination on the air conditioner may result in electric shock or 

fi

 re.

• 

Do not wash the air conditioner with water, as this may result in electric shock or 

fi

 re.

• 

Do not place water containers (vases, etc.) above the unit, as this may result in electric shock or 

fi

 re hazards if they should topple over.

• 

Do not insert the batteries in the wrong polarity (+/-) orientation as this may result in short circuiting, 

fi

 re, or battery leakage.

• 

To avoid oxygen depletion, ensure that the room is adequately ventilated if equipment such as a burner is used 

• 

together with the air conditioner.
Before cleaning, be sure to stop unit operation and turn off the circuit breaker. Otherwise, an electric shock and injury may result.

• 

Only connect the air conditioner to the speci

fi

 ed power supply circuit. Power supplies other than the one speci

fi

 ed 

• 

may result in electric shock, overheating and 

fi

 res.

Arrange the drain hose to ensure smooth drainage. Imperfect drainage may cause wetting of the building, furniture, etc.

• 

Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around 

• 

the unit. Leaves are a hotbed for small animals which can enter the unit. Once inside the unit, such animals can 
cause malfunctions, smoke or 

fi

 re if they come into contact with electrical parts.

Do not place objects around the indoor unit.

• 

Doing so may have an adverse in

fl

 uence on the performance, product quality, and life of the air conditioner.

This appliance is not intended to be used by persons with reduced physical, sensory or mental capabilities, or with 

• 

lack of operation knowledge, unless they have been given supervision or instruction concerning the appliance use by 
person responsible for their safety. Keep out of children’s reach to ensure that they do not play with the appliance.

FFP008

Installation site

To install the air conditioner in the following types of environments, consult your dealer.

 

Places with an oily environment or where steam or soot occurs.

• 

Salty  environments such as coastal areas.

• 

Places where sulphide gas occurs such as hot springs.

• 

Places where snow may block the outdoor unit.

• 

Be sure to follow the instructions below.

 

The indoor unit is at least 1m away from any television or radio set (unit may cause interference with the picture or sound).

• 

The drain from the outdoor unit must be discharged to a place of good drainage.

• 

Consider nuisance to your neighbours from noises

For installation, choose a place as described below.

 

A place solid enough to bear the weight of the unit and which does not amplify the operation noise or vibration.

• 

A place from where the air discharged from the outdoor unit or the operation noise will not annoy your neighbours.

• 

Electrical work

For the power supply, be sure to use a separate power circuit dedicated to the air conditioner.

 

System relocation

Relocating the air conditioner requires specialized knowledge and skills. Please consult your dealer if relocation 

 

is necessary for moving or remodelling.

01_EN_3P278434-5C.indd   3

01_EN_3P278434-5C.indd   3

8/18/2016   1:21:05 PM

8/18/2016   1:21:05 PM

Summary of Contents for FVXS35KV1A

Page 1: ...MODELS FVXS25KV1A FVXS35KV1A FVXS50KV1A FVXS25RV1A FVXS35RV1A FVXS45RV1A DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL Enjoy year round comfort 00_CV_3P278434 4C fm Page 1 Wednesday July 6 2016 2 32 PM...

Page 2: ......

Page 3: ...L HEAT FAN Operation 10 Adjusting the Airflow Direction 12 POWERFUL Operation 14 OUTDOOR UNIT QUIET Operation 15 ECONO Operation 16 TIMER Operation 17 WEEKLY TIMER Operation 19 Note for Multi System 2...

Page 4: ...s safe and normally does not leak However in the event of a leakage contact with a naked burner heater or cooker may result in generation of noxious gas Do not use the air conditioner until a qualifie...

Page 5: ...k and injury may result Only connect the air conditioner to the specified power supply circuit Power supplies other than the one specified may result in electric shock overheating and fires Arrange th...

Page 6: ...um fins on the inside of the indoor unit as it may result in injury 1 2 6 5 12 2 4 7 8 3 9 13 10 11 14 15 Air outlet selection switch This setting blows air from upper outlet only This setting automat...

Page 7: ...missing 12 Model name plate 13 Signal receiver It receives signals from the remote controller When the unit receives a signal you will hear a short beep Operation start beep beep Settings changed bee...

Page 8: ...ODE selector button It selects the operation mode AUTO DRY COOL HEAT FAN page 10 8 QUIET button OUTDOOR UNIT QUIET operation page 15 9 ECONO button ECONO operation page 16 10 SWING button Adjusting th...

Page 9: ...a long time take the batteries out The batteries will last for approximately 1 year If the remote controller display begins to fade and the degradation of reception performance occurs within a year ho...

Page 10: ...ent time Holding down or button rapidly increases or decreases the time display 5 Press CLOCK button Point the remote controller at the indoor unit when pushing the buttons when setting the indoor uni...

Page 11: ...ons Operation outside this humidity or temperature range may cause a safety device to disable the system Recommended temperature setting For cooling 26 28 C For heating 20 24 C Mode Operating conditio...

Page 12: ...the mode setting in sequence AUTO DRY COOL HEAT FAN 2 Press ON OFF button The OPERATION lamp lights green To stop operation 3 Press ON OFF button again The OPERATION lamp goes off To change the temper...

Page 13: ...he outdoor unit and lower the heating capacity In that case the system switches into defrosting operation to take away the frost During defrosting operation hot air does not flow out of indoor unit No...

Page 14: ...he knob and move the louvers You will find a knob on the left side and the right side blades Notes on flap and louvers angle Unless SWING is selected you should set the flap at a near horizontal angle...

Page 15: ...r conditioner Air is emitted only from the upper air outlet so that air does not come into direct contact with people and indoor temperature is equalized HEAT When the operation is activated or when a...

Page 16: ...ichever button is pressed last POWERFUL operation can only be set when the unit is running Pressing the operation stop button causes the settings to be canceled and the disappears from the LCD POWERFU...

Page 17: ...ated indoor units However if using priority room setting see note for multi system page 24 This function is available in COOL HEAT and AUTO operation This is not available in FAN and DRY operation POW...

Page 18: ...ion ECONO operation can only be set when the unit is running Pressing the operation stop button causes the settings to be canceled and the disappears from the LCD ECONO operation is a function which e...

Page 19: ...IMER button again The TIMER lamp lights yellow To cancel the OFF TIMER operation 4 Press CANCEL button The TIMER lamp goes off NOTE Notes on TIMER operation When TIMER is set the present time is not d...

Page 20: ...rapidly 3 Press ON TIMER button again The TIMER lamp lights yellow To cancel ON TIMER operation 4 Press CANCEL button The TIMER lamp goes off To combine ON TIMER and OFF TIMER A sample setting for com...

Page 21: ...ON ON ON ON settings for example makes it possible to schedule operating mode and set temperature changes Furthermore by using OFF OFF OFF OFF settings only the turn off time of each day can be set T...

Page 22: ...button changes or setting in sequence In case the reservation has already been set selecting blank deletes the reservation Go to STEP 9 if blank is selected 5 Press NEXT button The ON OFF TIMER mode w...

Page 23: ...forget to set the clock on the remote controller first The day of the week ON OFF TIMER mode time and set temperature only for ON TIMER mode can be set with WEEKLY TIMER Other settings for ON TIMER ar...

Page 24: ...ays of the week repeat STEP 4 and STEP 5 6 Press button to complete the setting is displayed on the LCD and WEEKLY TIMER operation is activated NOTE Copy mode COPY MODE The entire reservation of the s...

Page 25: ...the last reservation mode will be used To delete reservations Refer to page 20 When selecting desired mode at STEP 4 in setting mode select blank The reservation will be deleted This function can be u...

Page 26: ...is activated when the temperature drops 6 C or more below the highest temperature recorded that day Therefore when the temperature difference is less than 4 C this function will not be activated NIGHT...

Page 27: ...mode of the priority room takes precedence the user can select a different operation mode from other rooms Room A is the priority room in the examples Example When COOL operation is selected in room A...

Page 28: ...laces Attach the string to the right inner side of the front grille Close the panel slowly CAUTION Units Do not touch the metal parts of the indoor unit If you touch those parts this may cause an inju...

Page 29: ...lukewarm water then dry them up in the shade It is recommended to clean the air filter every 2 weeks Titanium apatite photocatalytic air purifying filter The titanium apatite photocatalytic air purify...

Page 30: ...op where you bought the air conditioner Dispose of old filters as flammable waste Check that the base stand and other fittings of the outdoor unit are not decayed or corroded Check that nothing blocks...

Page 31: ...ion Blowing sound This sound is generated when the flow of the refrigerant in the air conditioner is switched over Ticking sound This sound is generated when the size of the air conditioner slightly e...

Page 32: ...a breaker turned off or a fuse blown Isn t it a power failure Are batteries set in the remote controller Is the timer setting correct Cooling Heating effect is poor Is the air filter clean Is there a...

Page 33: ...g in poor performance It is recommended to have periodical maintenance by a specialist aside from regular cleaning by the user For specialist maintenance contact the service shop where you bought the...

Page 34: ...UCTION AIR TEMPERATURE SENSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E1 CIRCUIT BOARD FAULT E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT E8 OVERCURRENT INPUT F3 HIGH TEMP...

Page 35: ......

Page 36: ...1608 HT 3P278434 4C M16B095 The two dimensional bar code is a manufacturing code 00_CV_3P278434 4C fm Page 2 Wednesday July 6 2016 2 32 PM...

Page 37: ...DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FVXS60LVMA FVXS71LVMA FVXS50RV1A 00_CV_3P278434 5C indd 1 00_CV_3P278434 5C indd 1 7 5 2016 3 24 40 PM 7 5 2016 3 24 40 PM...

Page 38: ......

Page 39: ...EAT FAN Operation 10 Adjusting the Airflow Direction 12 POWERFUL Operation 14 OUTDOOR UNIT QUIET Operation 15 ECONO Operation 16 TIMER Operation 17 WEEKLY TIMER Operation 19 CARE Care and Cleaning 26...

Page 40: ...rsonal injury To avoid electric shock do not operate with wet hands Beware of fire in case of refrigerant leakage If the air conditioner is not operating correctly i e not generating cool or warm air...

Page 41: ...may result Only connect the air conditioner to the specified power supply circuit Power supplies other than the one specified may result in electric shock overheating and fires Arrange the drain hose...

Page 42: ...o start operation Push once again to stop it The operation mode refers to the following table Mode Temperature setting Airflow rate AUTO 25 C AUTO This switch is useful when the remote controller is m...

Page 43: ...el Page 26 Appearance of the outdoor unit may differ from some models Air outlet selection switch Page 13 Refrigerant piping humidifying hose and inter unit cable Earth terminal It is inside of this c...

Page 44: ...approximately 7m FAN setting button It selects the airflow rate setting Page 11 POWERFUL button POWERFUL operation Page 14 Display LCD It displays the current settings In this illustration each secti...

Page 45: ...tion Page 19 ON TIMER button Page 18 CLOCK button Page 9 OFF TIMER button Page 17 TIMER CANCEL button It cancels the timer setting Page 17 18 It cannot be used for the WEEKLY TIMER operation SELECT bu...

Page 46: ...time take the batteries out The batteries will last for approximately 1 year If the remote controller display begins to fade and the degradation of reception performance occurs within a year however r...

Page 47: ...ditioner always consumes a small amount of electricity even while it is not operating If you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker...

Page 48: ...the LCD The OPERATION lamp lights green Control panel To stop operation Press again disappears from the LCD The OPERATION lamp goes off To change the temperature setting Press or The displayed items o...

Page 49: ...t and lower the heating capacity In that case the system switches into defrosting operation to take away the frost During defrosting operation hot air does not flow out of indoor unit Note on COOL ope...

Page 50: ...u should set the flap at a near horizontal angle in FAN or HEAT operation and at a upward position in COOL or DRY operation to obtain the best performance COOL DRY FAN HEAT CAUTION Do not try to adjus...

Page 51: ...on is activated or when air emitted is of low temperature Air is emitted only from the upper air outlet so that air does not come into direct contact with people At times other than the above situatio...

Page 52: ...ction of whichever button is pressed last POWERFUL operation can only be set when the unit is running Pressing the operation stop button causes the settings to be canceled and the disappears from the...

Page 53: ...T and AUTO operation This is not available in FAN and DRY operations POWERFUL operation and OUTDOOR UNIT QUIET operation cannot be used at the same time Priority is given to the function of whichever...

Page 54: ...ses only The maximum running current and power consumption of the air conditioner in ECONO operation vary with the connecting outdoor unit NOTE Notes on ECONO operation ECONO Operation can only be set...

Page 55: ...lights yellow Control panel To cancel OFF TIMER operation Press and setting time disappear from the LCD and day of the week are displayed on the LCD The TIMER lamp goes off NOTE Notes on TIMER operati...

Page 56: ...ed on the LCD The TIMER lamp lights yellow Control panel To cancel ON TIMER operation Press and setting time disappear from the LCD and day of the week are displayed on the LCD The TIMER lamp goes off...

Page 57: ...me as those for Monday Page 22 6 00 8 30 17 30 22 00 25 C 27 C Program 1 Program 2 Program 3 Program 4 ON OFF ON OFF Saturday No timer settings Sunday Make timer settings up to programs 1 4 Page 20 8...

Page 58: ...ttings can be made per day Press 2 to select the desired day of the week and reservation number Pressing changes the reservation number and the day of the week Press 3 The day of the week and reservat...

Page 59: ...r another day of the week Refer to Copy mode Page 22 NOTE Notes on WEEKLY TIMER operation Do not forget to set the clock on the remote controller first Page 9 The day of the week ON OFF TIMER operatio...

Page 60: ...he week will be copied Press 4 to select the destination day of the week Press 5 The reservation will be copied to the selected day of the week The whole reservation of the selected day of the week wi...

Page 61: ...vation number to be confirmed Pressing displays the reservation details To change the confirmed reserved settings select the reservation number and press The mode is switched to setting mode Go to Set...

Page 62: ...f the week and the reservation number will be displayed Press 2 to select the day of the week and the reservation number to be deleted Press 3 and or blink Pressing changes ON OFF TIMER operation The...

Page 63: ...d Hold 3 for about 5 seconds The reservation of the selected day of the week will be deleted Press 4 If there are still other reservations WEEKLY TIMER operation will be activated All reservations Hol...

Page 64: ...he grooves of the unit 3 places Attach the string to the right inner side of the front grille Close the panel slowly Slide the 2 stoppers on the left and right sides outward until they click String St...

Page 65: ...nt panel Operation without air filter may result in troubles as dust will accumulate inside the indoor unit Insert the 2 tabs on the lower side of air filter into the body Then insert the 2 tabs on th...

Page 66: ...wed by washing it with water once every 6 months We recommend replacing it once every 3 years Material paper polypropylene Maintenance Vacuum dusts and soak in warm water or water for about 10 to 1 15...

Page 67: ...fittings of the outdoor unit are not decayed or corroded Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit Check that the drain comes smoothly out of the...

Page 68: ...w of the refrigerant in the air conditioner is switched over Ticking sound This sound is generated when the size of the air conditioner slightly expands or shrinks as a result of temperature changes C...

Page 69: ...ioner with the remote controller The flap does not start swinging immediately The air conditioner is adjusting the flap position The flap will start moving soon Case Explanation The outdoor fan rotate...

Page 70: ...om the indoor unit Turn the breaker off and call the service shop After a power failure The air conditioner automatically resumes operation in about 3 minutes You should just wait for a while Lightnin...

Page 71: ...RATURE SENSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E1 CIRCUIT BOARD FAULT E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT E8 OVERCURRENT INPUT F3 HIGH TEMPERATURE DISCHARG...

Page 72: ...3P278434 5C M16B096 1608 HT The two dimensional bar code is a manufacturing code 00_CV_3P278434 5C indd 2 00_CV_3P278434 5C indd 2 7 5 2016 3 24 42 PM 7 5 2016 3 24 42 PM...

Reviews: