3 User safety instructions

Installation and operation manual

5

FXDA10~63A2VEB
VRV system air conditioner
3P599562-1 – 2020.05

WARNING

If the supply cord is damaged, it MUST be replaced by the
manufacturer,  its  service  agent  or  similarly  qualified
persons in order to avoid a hazard.

CAUTION

▪ Each  indoor  unit  has  to  be  connected  to  a  separate

user interface. Only a safety system compatible remote
controller  can  be  used  as  the  user  interface.  See
technical  data  sheet  for  remote  controller  compatibility
(e.g. BRC1H52/82*).

▪ The  user  interface  has  to  be  put  in  the  same  room  as

the  indoor  unit.  For  details,  please  refer  to  the
installation and operation manual of the user interface.

For the user

3

User safety instructions

Always observe the following safety instructions and regulations.

3.1

General

WARNING

If you are NOT sure how to operate the
unit, contact your installer.

WARNING

This appliance is not intended for use
by persons, including children, with
reduced physical, sensory or mental
capabilities, or lack of experience and
knowledge, unless they have been
given supervision or instruction
concerning use of the appliance by a
person responsible for their safety.

Children should be supervised to
ensure that they do not play with the
appliance.

Cleaning and user maintenance must
not be carried out by children without
supervision.

WARNING

To prevent electrical shocks or fire:

▪ Do NOT rinse the unit.

▪ Do NOT operate the unit with wet

hands.

▪ Do NOT place any objects containing

water on the unit.

CAUTION

▪ Do NOT place any objects or

equipment on top of the unit.

▪ Do NOT sit, climb or stand on the

unit.

▪ Units are marked with the following symbol:

This  means  that  electrical  and  electronic  products  may  NOT  be
mixed  with  unsorted  household  waste.  Do  NOT  try  to  dismantle
the  system  yourself:  the  dismantling  of  the  system,  treatment  of
the  refrigerant,  of  oil  and  of  other  parts  must  be  done  by  an
authorized installer and must comply with applicable legislation.
Units must be treated at a specialized treatment facility for reuse,
recycling  and  recovery.  By  ensuring  this  product  is  disposed  of
correctly, you will help to prevent potential negative consequences
for  the  environment  and  human  health.  For  more  information,
contact your installer or local authority.

▪ Batteries are marked with the following symbol:

This  means  that  the  batteries  may  NOT  be  mixed  with  unsorted
household  waste.  If  a  chemical  symbol  is  printed  beneath  the
symbol,  this  chemical  symbol  means  that  the  battery  contains  a
heavy metal above a certain concentration.
Possible chemical symbols are: Pb: lead (>0.004%).
Waste batteries must be treated at a specialized treatment facility
for  reuse.  By  ensuring  waste  batteries  are  disposed  of  correctly,
you  will  help  to  prevent  potential  negative  consequences  for  the
environment and human health.

3.2

Instructions for safe operation

WARNING

▪ Do not modify, disassemble, remove,

reinstall or repair the unit yourself as
incorrect dismantling or installation
may cause an electric shock or fire.
Contact your dealer.

Summary of Contents for FXDA10A2VEB

Page 1: ...and operation manual VRV system air conditioner English Installation and operation manual VRV system air conditioner FXDA10A2VEB FXDA15A2VEB FXDA20A2VEB FXDA25A2VEB FXDA32A2VEB FXDA40A2VEB FXDA50A2VEB...

Page 2: ...v e cu condi ia ca acestea s fie utilizate n conformitate cu instruc iunile noastre skladni z naslednjimi standardi in drugimi normativi pod pogojem da se uporabljajo v skladu z na imi navodili on vas...

Page 3: ...ndoor unit 17 15 Commissioning 18 15 1 Checklist before commissioning 18 15 2 To perform a test run 19 16 Configuration 19 16 1 Field setting 19 17 Technical data 20 17 1 Wiring diagram 20 17 1 1 Unif...

Page 4: ...ill not come into direct contact with people Do NOT use booster fans in the duct Use the function to adjust the fan rate setting automatically see 16 1 Field setting 419 Refrigerant piping installatio...

Page 5: ...operate the unit with wet hands Do NOT place any objects containing water on the unit CAUTION Do NOT place any objects or equipment on top of the unit Do NOT sit climb or stand on the unit Units are...

Page 6: ...or your health to expose your body to the air flow for a long time CAUTION To avoid oxygen deficiency ventilate the room sufficiently if equipment with burner is used together with the system CAUTION...

Page 7: ...or a cooker this may result in fire or the formation of a harmful gas Turn off any combustible heating devices ventilate the room and contact the dealer where you purchased the unit Do NOT use the un...

Page 8: ...discoloured or the coating peeled off If it is heavily dirty soak a cloth in water diluted neutral detergent squeeze it well and wipe the panel clean Wipe it with another dry cloth NOTICE NEVER press...

Page 9: ...ver replace a fuse with a fuse of a wrong ampere ratings or other wires when a fuse blows out Use of wire or copper wire may cause the unit to break down or cause a fire CAUTION After a long use check...

Page 10: ...r to ensure smoother operation As soon as the power is turned on the user interface display appears Insert batteries in the user interface if applicable 7 5 About the refrigerant This product contains...

Page 11: ...INFORMATION The minimum airflow during normal operation or during the refrigerant leakage detection is always 240 m3 h 8 Troubleshooting If one of the following malfunctions occur take the measures sh...

Page 12: ...tion in an environment with a lot of organic solvents such as ink and siloxane WARNING The appliance shall be stored in a room without continuously operating ignition sources example open flames an op...

Page 13: ...door unit 12 2 Mounting the indoor unit 12 2 1 Guidelines when installing the indoor unit INFORMATION Optional equipment When installing optional equipment also read the installation manual of the opt...

Page 14: ...wooden structure separate the duct and wall electrically Install the outlet grille in a position where the airflow will not come into direct contact with people Do NOT use booster fans in the duct Use...

Page 15: ...and T joints with the correct gauge for the operating capacity of the units 100 600 mm a a T joint To connect the drain piping to the indoor unit NOTICE Incorrect connection of the drain hose might ca...

Page 16: ...of the user interface 2 Gradually pour approximately 1 l of water through the water inlet and check for leaks see When installation of the system is not yet completed 416 13 Piping installation 13 1 P...

Page 17: ...rom the base of the unit to the top of the flare nut NOTICE Make sure to insulate all refrigerant piping Any exposed piping might cause condensation 14 Electrical installation DANGER RISK OF ELECTROCU...

Page 18: ...1 T2 P1 P2 F1 F2 T1 T2 P1 P2 F1 F2 T1 T2 P1 P2 F1 F2 T1 T2 N L a d c b L N N L N L N L a Outdoor unit b Indoor unit c User interface d Most downstream indoor unit NOTICE Group control connection is NO...

Page 19: ...x 3 0 02 3 0 x 3 5 03 Setting Static pressure Change the value number in accordance with the external static pressure of the duct to be connected as in the table below See technical documentation for...

Page 20: ...subset of the latest technical data is available on the regional Daikin website publicly accessible The full set of latest technical data is available on the Daikin Business Portal authentication req...

Page 21: ...ker Q DI KLM Earth leak circuit breaker Q L Overload protector Q M Thermo switch Q R Residual current device R Resistor R T Thermistor RC Receiver S C Limit switch S L Float switch S NG Refrigerant le...

Page 22: ......

Page 23: ......

Page 24: ...3P599562 1 2020 05 Copyright 2020 Daikin Verantwortung f r Energie und Umwelt...

Reviews: