FXDQ-SPV1 EDTFVN391825
27
3P347455-11H
2
2-3 Optional parts
(b) Places in which corrosive gas can be generated, such
as sulfur dioxide.
The copper pipes or welded parts can be corroded
and lead to refrigerant leakage.
(c) Places near any machine which generates
electromagnetic wave.
Electromagnetic wave can have influence on the
control system, so the air conditioner cannot work
properly.
(d) Places in which any combustible gas is leaked out, any
carbon fiber or combustible powder floats, or volatile
combustible gas such as gasoline or thinner is stored.
In case that the air conditioner is used in such places,
fire can occur.
·
Please never touch any fin of the heat exchanger.
Improper touching can cause damages.
·
Please pay special attention to the transport of the product.
PP packing straps are used for some products. Please
never lift and pull the PP packing straps to transport.
It is dangerous.
·
For the sake of safety, please discard the packing materials.
Packing materials such as nails and timbers can lead to
stabbings or other harms.
Please tear off and discard the plastic bags, so as to
prevent children from playing with plastic bags and leading
to suffocation.
·
Please do not switch off the power supply when the
operation is just stopped.
Please wait for at least 5 minutes before switching off the
power supply.
Otherwise water leakage and other problems can occur.
·
Depending on different setting environment, electromagnetic
interference can occur for different products.
In this case, keep proper distance from the product.
Please follow the State standards to carry out the
installation work.
2. BEFORE INSTALLATION
Before the installation work is completed, please
never discard any accessory which may be required
during installation. Never discard!
1. Determine the route for moving in the air conditioner
in advance.
2. Before moving the air conditioner to the place of
installation, never unpack it. In cases that the air
conditioner has to be unpacked, soft ropes shall be
used when hoisted up or a protection plate shall be
placed in the point of the hoisting cable, so as to
prevent the air conditioner from damage or scratching.
When moving the air conditioner whether when it is
being unpacked or after it is unpacked, please hold
the hoisting bracket base. Never apply force on the
refrigerant pipe, water drainage pipe or plastic parts.
Before installing the air conditioner, please confirm
whether the refrigerant used is R410A refrigerant.
For the installation of the outdoor unit, please make
references to the installation manual for the outdoor unit.
2-1 Notes
·
Please tell the correct operating methods of the various
functions as well as the temperature adjustment
methods of the air conditioner to the user, and ask the
user to read the operation manual and carry out
operations at the same time.
·
The air conditioner is not suitable to be installed in
places in which high content of salt is contained in the air,
such as coast; and is not suitable in places in which the
fluctuation of voltage is high, such as factory.
The air conditioner is also not suitable to be used in
vehicles or ships.
2-2 Accessories
Please check whether the following articles are supplied
with the air conditioner.
Name
Metal clip (1)
Water drainage
hose (2)
Insulation piece
for connector
Seal
Quantity
1 piece
1 piece
1 piece each
1 piece each
Shape
For liquid pipe (3)
Large (5)
For air pipe (4)
Middle (6)
Name
Bolt for flange
connection (7)
Washer for hoisting
bracket base (8)
Banding tie
Quantity
1 set
8 pieces
1 set
Shape
Large (9)
8 pieces
16 pieces
Small (10)
4 pieces
Name
Quantity
Shape
Washer positioning
plate (11)
Seal (12)
4 pieces
2 pieces
(Other)
• Operation manual
• Installation manual
• Conforming certificate
of product
·
The indoor unit needs one remote control for operations
as listed in the following table.
Remote control
Applicable model
Wired R/C
Wireless
R/C
H/P
C/O
BRC1C62 (3 ranges)
FXDQ
~
SPV1
a. Key points to be inspected after completion of
installation.
During installation work and during inspection after
completion of installation, pay special attention to
the following points.
Items of Inspection
Are the indoor unit and outdoor
unit installed firmly?
Has air leakage inspection been
carried out?
Is the heat insulation good?
(Refrigerant pipe, water
drainage pipe and air pipe)
Is water smoothly drained off?
Is the power voltage consistent
with the one specified on the
nameplate of the machine?
Is the connection of the cable
and the pipe correct?
Is the air conditioner safely
grounded?
Are cables with the specified
specifications used?
Are the suction inlet and air
blow outlet of the indoor unit
and the outdoor unit blocked by
anything?
Have the length of the refrigerant
pipe and the filled amount of
refrigerant been recorded?
Results possibly occurring
in case of any error
Inspected
and signature
At the same time, please make references to Section
“SAFETY PRECAUTIONS”.
The air conditioner falls off,
vibrates and sends out noise.
There is no sufficient cool air
or hot air.
Condensate drips off.
Water leaks out.
The machine cannot work
normally or parts are burnt off.
The machine cannot work
normally or parts are burnt off.
Once there is electricity
leakage, it is very dangerous.
The machine cannot work
normally or parts are burnt off.
There is no sufficient cool air
or hot air.
The amount of the refrigerant
of the air conditioning system
is unknown.
BRC1E62 (3 ranges)
BRC4C65 (3 ranges)
BRC4C66 (3 ranges)
Summary of Contents for FXDQ-SPV1
Page 1: ...FXDQ SPV1 EDTFVN391825 201803 Engineering Data 50 Hz...
Page 2: ......
Page 8: ...FXDQ SPV1 EDTFVN391825 6 3 Dimensions FXDQ20SPV1 FXDQ25SPV1 FXDQ32SPV1 3D071829D Unit mm...
Page 9: ...FXDQ SPV1 EDTFVN391825 7 FXDQ40SPV1 FXDQ50SPV1 3D071831D Unit mm...
Page 10: ...FXDQ SPV1 EDTFVN391825 8 FXDQ63SPV1 3D071830D Unit mm...
Page 17: ...FXDQ SPV1 EDTFVN391825 15 9 Fan Performances FXDQ20SPV1 3D072697C...
Page 18: ...FXDQ SPV1 EDTFVN391825 16 FXDQ25SPV1 3D072698C...
Page 19: ...FXDQ SPV1 EDTFVN391825 17 FXDQ32SPV1 3D090527...
Page 20: ...FXDQ SPV1 EDTFVN391825 18 FXDQ40SPV1 FXDQ50SPV1 3D072702C...
Page 21: ...FXDQ SPV1 EDTFVN391825 19 FXDQ63SPV1 3D090542...
Page 22: ...FXDQ SPV1 EDTFVN391825 20 10 Sound Levels FXDQ20SPV1 FXDQ25SPV1 4D090507A 4D090508A...
Page 23: ...FXDQ SPV1 EDTFVN391825 21 FXDQ32SPV1 FXDQ40SPV1 FXDQ50SPV1 4D090509A 4D090510A...
Page 24: ...FXDQ SPV1 EDTFVN391825 22 FXDQ63SPV1 4D090511A...
Page 26: ...FXDQ SPV1 EDTFVN391825 24 FXDQ63SPV1 4D072720H Unit mm...
Page 41: ......
Page 42: ......
Page 43: ......