SiBE041025
Troubleshooting
Service Diagnosis
69
Troubleshooting
Check No.06
Refer to P.86
Check No.07
Refer to P.87
Check No.08
Refer to P.87
Check No.09
Refer to P.88
(R11988)
Caution
Replace the fan motor.
Reconnect the connector or
fan motor lead wires.
Replace the stop valve.
Replace the outdoor heat
exchanger thermistor.
Replace the capillary tube.
Completed.
Clean the outdoor heat
exchanger.
Change the installation
location or direction.
Check the installation space.
Replace the outdoor unit PCB.
NG
NO
OK
NG
OK
OK
OK
NG
YES
NG
Check No. 09
Check the outdoor fan.
Check No. 08
Check the discharge
pressure.
Check No. 06
Check the outdoor heat
exchanger thermistor.
Error again?
Check No. 07
Check the installation
condition.
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.