8
English
Press the air flow direction adjust but-
ton to select the air direction of your
choice.
The air flow flap display stops swing-
ing and the air flow direction is fixed.
(Fixed air flow direction setting)
MOVEMENT OF THE AIR FLOW FLAP
For the following conditions, a micro computer con-
trols the air flow direction which may be different
from the display.
The air flow direction can be adjusted in one of the
following ways.
• The air flow flap itself adjusts its position.
• The air flow direction can be fixed by the user.
Automatic “
” or desired position “
”.
NOTE
• The movable limit of the flap is changeable.
Contact your Daikin dealer for details. (Only
for Double-flow, Multi-flow, Corner, Ceiling-
suspended and Wall-mounted.)
• Avoid operating in the horizontal direction
“
”. It may cause dew or dust to settle on
the ceiling.
Fig.5
5-4 PROGRAMMING START AND STOP OF
THE SYSTEM WITH TIMER
• The timer is operated in the following two ways.
Programming the stop time “
”. The system
stops operating after the set time has elapsed.
Programming the start time “
”. The system
starts operating after the set time has elapsed.
• The timer can be programmed for a maximum of
72 hours.
• The start and the stop time can be simultaneously
programmed.
Fig.6
Press the timer mode start/stop button several
times and select the mode on the display.
The display flashes.
• For setting the timer stop “
”
• For setting the timer start “
”
Press the programming time button and set
the time for stopping or starting the system.
Each time this button is pressed, the
time advances or goes backward by 1
hour.
Press the timer on/off button.
The timer setting procedure ends. The display
“
” or “
” changes from flashing
light to constant light.
NOTE
• When setting the timer off and on at the
same time, repeat the above procedure
(from “
” to “
”) once again.
• After the timer is programmed, the display
shows the remaining time.
• Press the timer on/off button once again to
cancel programming. The display vanishes.
COOLING
HEATING
• When starting operation.
• When the room temperature is
higher than the set temperature.
• At defrost operation.
• When operating continuously at horizontal air flow direction.
• When continuous operation with downward air flow is performed at the
time of cooling with a ceiling-suspended or a wall-mounted unit, the
micro-computer may control the flow direction, and then the remote con-
trol indication also will change.
2
Double-flow
Ceiling Suspended
Multi-flow
1
2
3
1
2