1-22
1.7 Information Interchange with Personal Computer
The electronic controller has an internal memory function to record the set point temperature, refrigeration
temperature, operation mode, alarm and the report of automatic PTI during transportation in addition to the
normal operation control.
Data download
Data records can be downloaded by connecting a PC to the communication port. Furthermore, all of the
recorded data inside the controller can be downloaded by inserting a USB memory into the connection port
of the controller.
Software upload
The software in the controller can be updated by uploading software using a PC or USB memory.
The use of a PC also enables the container number, cargo description, destination and other information to
be sent to and memorized in the controller.
Description
PC connection
USB memory connection
Download
Trip report
FULL TRIP
✓
✓
All data are downloaded
in a lump.
LAST ONE TRIP
✓
TRIP BY DATE
✓
TRIP BY TRIP
✓
PTI report
✓
USDA report
✓
Monitoring report
✓
✓
Upload
Software upload
✓
✓
Container No. etc. upload
✓
Note 1. Download the file with authentication into a USB memory from the web site.
2. See
※
14-1 and
※
14-2 menu in paragraph 2.3 for the procedure of downloading and uploading by
connecting a USB memory.
3. When you see the downloading data from USB memory by PC, install the DCCS software (ver. 9
series) in advance.
PC connected to the communication port
USB memory connected to the controller
USB memory insert port
01̲01-22̲LX10F11B̲En.indd 1-22
01̲01-22̲LX10F11B̲En.indd 1-22
2014/11/19 16:40:37
2014/11/19 16:40:37
https://daikin-p.ru
Summary of Contents for LX10F11B
Page 2: ...Revision A Correction of spelling 2012 9 28 https daikin p ru...
Page 6: ...https daikin p ru...
Page 82: ...https daikin p ru...
Page 92: ...https daikin p ru...
Page 127: ...5 9 5 6 Sequence https daikin p ru...
Page 128: ...5 10 Stereoscopic wiring diagram https daikin p ru...
Page 129: ...Revision A Correction of spelling 2012 9 28 https daikin p ru...