2-2
2.1 Operation Panel
●
ALARM LED (Red)
ALARM LED blinks in case of F alarms or E807
and E304.
●
IN RANGE LED (Green)
Lights when the control temperature is in range.
IN RANGE LED
OFF
IN RANGE LED
OFF
SP
SP+1
℃
SP-2
℃
SP+2
℃
SP-1
℃
SP
IN RANGE LED
ON
●
DEFROST LED (orange)
Lights when defrosting control is being carried out.
●
DEHUMID LED (yellow)
Lights when dehumidifying is set to ON (including
ON-A and Bulb settings).
●
Function of operation key
UNIT
ON/OFF
To start or to stop the unit operation.
If the power supply is cut off while the
unit is on, and the power supply is then
turned on again, the unit automatically
starts the operation without pressing
this key again.
UP
DOWN
• Scroll up or down to select an item
• Determine the setting item
LEFT
RIGHT
• Scroll right or left to select an item
• Move to next or previous screen
MENU
• To move to Battery Mode display
when no power is supplied
• To move to Initialize Menu display
after unit ON/OFF key "ON"
• To move to Menu display while
the unit is in operation
ENTER
• To determine the setting contents
ESC
• Returns from the display contents
to the previous screen.
MANUAL
DEFROST
• To carry out manual defrost
operation
FULL COOL
COOLING OFF
MODULATION
HEATING
HEATING OFF
DEFROST
EMERGENCY STOP
EMERGENCY SHUTDOWN
*2 Supply air Temp.
Control humidity
Set Point temperature
Defrost interval
Humidity setting
Setting mode
Operation condition
MENU
RIGHT
UP
LEFT
DOWN
ESC
ENTER
Reserve
MANUAL
DEFROST
LP: 20kPa
FULL COOL
DEF-INT 12HR
SET-HU 70%RH
SET-MODE
DEHUMID
USDA
ASC
ACT
G-Set
*1 Return air Temp.
FROZEN
SUPPLY -18.6
℃
HP
:
1200kPa
SET POINT
-18.0
℃
HUMID 75%RH
RETURN
-18.1
℃
▼
▲
UNIT
ON/OFF
LCD panel
LED light
Operation key
HPT & LPT *3
*1 Supply air temp. is displayed in chilled mode.
*2 Return air temp. is displayed in chilled mode.
*3 Other sensor values can be checked in
"Sensor Information" menu.
ALARM LED
ALARM
IN RANGE
DEFROST
DEHUMID
IN RANGE LED
DEFROST LED
DEHUMID LED
02̲01-18̲LX10F11B̲En.indd 2-2
02̲01-18̲LX10F11B̲En.indd 2-2
2014/11/19 16:38:33
2014/11/19 16:38:33
https://daikin-p.ru
Summary of Contents for LX10F11B
Page 2: ...Revision A Correction of spelling 2012 9 28 https daikin p ru...
Page 6: ...https daikin p ru...
Page 82: ...https daikin p ru...
Page 92: ...https daikin p ru...
Page 127: ...5 9 5 6 Sequence https daikin p ru...
Page 128: ...5 10 Stereoscopic wiring diagram https daikin p ru...
Page 129: ...Revision A Correction of spelling 2012 9 28 https daikin p ru...