2-7
Mode Set screen
Mode Set display
Humidity Set
▲▼
:Change
ENTER:Confirm
▲▼
:Change
ENTER:Confirm
ON
Humidity Set
▲▼
:Change
ENTER:Confirm
Humidity Set
Bulb
Humidity Set
Evap Fan Speed
Def
End
Temp
Bulb
H-L
18.0
℃
Evap Fan Speed
Def End Temp
Bulb
L
18.. 0
℃
EFM speed setting
Defrost ending temperature setting
Evap Fan Speed
Def
End
Temp
Bulb
H-L
15.0
℃
ON-A
OFF
Press key to select "L", "H-L," or "H" for
EFM speed and press key to determine.
Press key to select the defrost
completion temperature in the range of 4.0
℃
to 18.0
℃
and press key to determine.
▲▼
:Change
ENTER:
Confirm
▲▼
:Change
ENTER:
Confirm
▲▼
:Change
ENTER:Confirm
<
Optional Functions
>
※
2-3 Humidity Set
1. Press
key to select
Humidity Setting and press
key to determine.
Humidity Setting
:
50
〜
95%RH
※
2-4 USDA Set
1. Press
key to select number of sensors and press
key to determine.
4 sensors
:
4 USDA sensors connected
3 sensors
:
3 USDA sensors connected
AUTO
:
Automatically recognize the number
of USDA sensors connected (Note 1)
OFF
:
No USDA sensor connected
Note 1: To measure the temperature inside or cargo
temperature for the purposes other than cold
treatment transport, USDA sensor can record the
temperature ranging from –30.0
℃
to +40
℃
.
Do not use it for cold transport treatment
because it does not meet the USDA standards.
Humidity Sepoint
▲▼
: Change
ENTER : Confirm
95 % RH
▲▼
: Change
ENTER : Confirm
Humidity Setpoint
75 % RH
USDA
▲▼
: Change
ENTER : Confirm
OFF
▲▼
: Change
ENTER : Confirm
4 sensors
USDA
02̲01-18̲LX10F11B̲En.indd 2-7
02̲01-18̲LX10F11B̲En.indd 2-7
2014/11/19 16:38:37
2014/11/19 16:38:37
https://daikin-p.ru
Summary of Contents for LX10F11B
Page 2: ...Revision A Correction of spelling 2012 9 28 https daikin p ru...
Page 6: ...https daikin p ru...
Page 82: ...https daikin p ru...
Page 92: ...https daikin p ru...
Page 127: ...5 9 5 6 Sequence https daikin p ru...
Page 128: ...5 10 Stereoscopic wiring diagram https daikin p ru...
Page 129: ...Revision A Correction of spelling 2012 9 28 https daikin p ru...