3-4
No.
Inspection item
Inspection content
PTI
Electr
ical system
1
Damage of power cable
and plug
✓
2
Inspect condition of
internal wiring
✓
3
Inspect electrical
connections and tighten as
needed
1) Magnetic switch
✓
2) Electrical contractors
✓
3) Terminal block
✓
4
Condition of monitoring
receptacle cover
✓
5 Condition of PC port cover
✓
6 Fuse conditions
Open or short connection
✓
7
Inspection of magnetic
switch contact
Contact point inspection
✓
8
Check electrical
insulation
1) Power cable and plug
✓
2) Compressor
✓
3) Condenser fan motor
✓
4) Evaporator fan motor
✓
9
Starting procedure
inspection
✓
10 Temperature sensor
1) Installation condition of sensor
✓
2) Alarm indication
✓
11
PT/CT (voltage and
current) Alarm indication
✓
12
Pressure sensor Alarm
indication
✓
13 Electronic controller
Check of wake-up battery
✓
14 Evaporator fan motor
1) Speed switchover
✓
2) Rotation direction
✓
15 Condenser fan motor
Rotating direction
✓
16 Evaporator fan
Deformation and damage
inspection
✓
17 Condenser fan
Deformation and damage
inspection
✓
Others
1
Check for abnormal noise
and vibration during
operation
✓
2
Temperature control
function
1) 0
℃
operation
✓
2) –18
℃
operation
✓
3 Defrost function
✓
4 Clean unit with fresh water
✓
03̲01-10̲LX10F11B̲En.indd 3-4
03̲01-10̲LX10F11B̲En.indd 3-4
2014/11/19 16:36:34
2014/11/19 16:36:34
https://daikin-p.ru
Summary of Contents for LX10F11B
Page 2: ...Revision A Correction of spelling 2012 9 28 https daikin p ru...
Page 6: ...https daikin p ru...
Page 82: ...https daikin p ru...
Page 92: ...https daikin p ru...
Page 127: ...5 9 5 6 Sequence https daikin p ru...
Page 128: ...5 10 Stereoscopic wiring diagram https daikin p ru...
Page 129: ...Revision A Correction of spelling 2012 9 28 https daikin p ru...