2-7
※
2-3 Bulb Mode Set
1. Press
or
key to select "ON" or "OFF" and press
key to determine.
ON : Bulb mode operation is conducted. (For unit equipped with humidity sensor)
OFF : Bulb mode operation is not conducted.
2. After selecting "ON", press
or
key to select "L", "H-L", or "H" for the EFM speed and press
key to determine.
3. Press
or
key to select the defrost completion temperature in the range of 4.0
℃
to 18.0
℃
and
press
key to determine.
※
If it is necessary to set the humidity, do so according to the procedure in 2-2 Dehumidification Set.
※
2-4 USDA Set
1. Press
key to select number of sensors and press
key to determine.
4 sensors
:
4 USDA sensors connected
3 sensors
:
3 USDA sensors connected
AUTO
:
Automatically recognize the number
of USDA sensors connected (Note 1)
OFF
:
No USDA sensor connected
Note 1: To measure the temperature inside or cargo
temperature for the purposes other than cold
treatment transport, USDA sensor can record the
temperature ranging from –30.0
℃
to +40
℃
.
Do not use it for cold transport treatment
because it does not meet the USDA standards.
USDA
▲▼
: Change
ENTER : Confirm
OFF
▲▼
: Change
ENTER : Confirm
4 sensors
USDA
Dehumidification Set
▲▼
:Change
ENTER:Confirm
▲▼
:Change
ENTER:Confirm
ON
Dehumidification Set
▲▼
:Change
ENTER:Confirm
95 % RH
Humidity Setpoint
▲▼
:Change
ENTER:Confirm
75 % RH
Humidity Setpoint
OFF
1. Dehumidification set
2. Humidity setpoint selection
Mode Set screen
Bulb mode
▲▼
:Change
ENTER:Confirm
▲▼
:Change
ENTER:Confirm
ON
Bulb mode
OFF
1. Bulb mode selection
2. EFM speed setting
3. Defrost completion temperature
Mode Set screen
Evap Fan Speed
Def
End
Temp
Bulb mode
18.0
℃
▲▼
:Change
ENTER:
Confirm
L
Evap Fan Speed
Def
End
Temp
Bulb mode
15.0
℃
▲▼
:Change
ENTER:
Confirm
L
02章01-18̲LX10F11B3̲TR16-02̲En.indd 2-7
02章01-18̲LX10F11B3̲TR16-02̲En.indd 2-7
2016/02/03 16:14:29
2016/02/03 16:14:29
https://daikin-p.ru
Summary of Contents for LX10F11B3
Page 7: ...https daikin p ru ...
Page 83: ...https daikin p ru ...
Page 93: ...https daikin p ru ...
Page 121: ...https daikin p ru ...
Page 129: ...https daikin p ru ...
Page 138: ...6 9 6 6 Sequence AIR WATER COOLED AIR WATER COOLED https daikin p ru ...
Page 139: ...6 10 Stereoscopic wiring diagram AIR WATER COOLED https daikin p ru ...