4-3
RM Circuit Check
ESC : Cancel
Connect Remote
Monitor Plug
Then Press Enter
RM Circuit Check
RM-Comp Circuit Check
RM-Defrost Circuit Check
RM-In Range Circuit Check
RM-Compressor Check
ESC OFF and Return
▲▼
: Change
ENTER : Confirm
OFF
RM-Compressor Check
ESC : OFF and Return
▲▼
: Change
ENTER : Confirm
ON
1/1
Normal
ESV
SV 1
SV 2
RM
R/F
ESV
SV 1
SV 2
RM
R/F
Error
I/O board
Manual Check
NEXT
PREV
2/3
RM ON/OFF
Comp ON/OFF
HuS-reading
All Sensor Calibration
----------
Follow the same procedure for other magnetic contactor or solenoid valve ON/OFF check.
※
2 PCC2 ON/OFF Check
※
3 CFH & PCC1 (or 2) ON/OFF Check
※
4 CFL & PCC1 (or 2) ON/OFF Check
※
5 EFH & PCC1 (or 2) ON/OFF Check
※
6 EFL & PCC1 (or 2) ON/OFF Check
※
7 HSV ON/OFF Check
※
8 RSV ON/OFF Check
※
9 LSV ON/OFF Check
※
10 ESV ON/OFF Check
※
11 RM (Remote Monitoring) Circuit Check (Option)
Follow the same procedure for RM-Defrost Circuit and RM-In Range Circuit checks.
※
11-2 RM-Defrost Circuit Check
※
11-3 RM-In Range Circuit Check
※
11-1 RM-Compressor Circuit Check
1. Press
key to
select "RM-ON/OFF"
and press
key to
determine.
2. Connect Remote
Monitoring plug.
1. Press
key to select RM-Compressor
Check and press
key to determine.
2. Press
key to select ON and press
key
to determine. RM I/O Board LED "ON" for fail or
"OFF" for pass.
3. It is error when LED (Red) for RM lights ON. (RM
circuit for compressor is shorted.)
It is normal when the LED lights OFF.
During checking, the
corresponded magnetic
contactor or solenoid valve
is energized and LED (I/O
board) lights ON (green).
During checking
※
3
〜
※
6, the corresponded fan
operation current will be
displayed.
PCC1
PCC2
CFH
CFL
EFH
CFH &PCC2 ON
CFH & PCC2 ON
Current 2.2A
▲▼
: Change
ENTER : Confirm
ON
I/O board
CFH &PCC2 ON
04章̲LX10F11B3̲TR16-02̲En.indd 4-3
04章̲LX10F11B3̲TR16-02̲En.indd 4-3
2016/02/03 16:21:58
2016/02/03 16:21:58
https://daikin-p.ru
Summary of Contents for LX10F11B3
Page 7: ...https daikin p ru ...
Page 83: ...https daikin p ru ...
Page 93: ...https daikin p ru ...
Page 121: ...https daikin p ru ...
Page 129: ...https daikin p ru ...
Page 138: ...6 9 6 6 Sequence AIR WATER COOLED AIR WATER COOLED https daikin p ru ...
Page 139: ...6 10 Stereoscopic wiring diagram AIR WATER COOLED https daikin p ru ...