28
6-8
Alarm code
Content
Possible cause
E406
Suction gas sensor (SGS)
Line breakage
malfunction
Short circuit
Wrong wiring
CPU board malfunction
E407
Evaporator inlet sensor (EIS)
Line breakage
malfunction
Short circuit
Wrong wiring
CPU board malfunction
E409
Evaporator outlet sensor
Line breakage
(EOS) malfunction
Short circuit
Wrong wiring
CPU board malfunction
E411
Ambient sensor (AMBS)
Line breakage
malfunction
Short circuit
Wrong wiring
CPU board malfunction
E413
Low pressure transducer
Line breakage
(LPT) malfunction
Short circuit
Wrong wiring
CPU board malfunction
E415
High pressure transducer
Line breakage
(HPT) malfunction
Short circuit
Wrong wiring
CPU board malfunction
E417
Voltage sensor (PT1)
Sensor malfunction
malfunction
CPU board malfunction
E419
Voltage sensor (PT2)
Sensor malfunction
malfunction
CPU board malfunction
E421
Current sensor (CT1)
Sensor malfunction
malfunction
CPU board malfunction
E423
Current sensor (CT2)
Sensor malfunction
malfunction
CPU board malfunction
E425
Pulp temperature sensor
Wrong wiring in the USDA receptacle.
E427
(USDA1 to 3) malfunction
Line breakage in the USDA receptacle.
E429
Short circuit in the USDA receptacle.
Junction cable breakage
Junction cable poor contact
Wrong wiring in the control box
Short circuit in the control box
Pulp temperature sensor malfunction
CPU board malfunction
E431
Humidity sensor (HuS)
Lead wire breakage
malfunction
Wrong wiring
Humidity sensor malfunction
CPU board malfunction
E603
Line breakage of suction
Lead wire breakage
modulating valve (SMV) or
Wrong wiring
drive circuit malfunction or
CPU board malfunction
wrong setting of controller
Wrong setting of initial setting of controller (DECOS a, b, c)
E607
Abnormal contact point of
Switch malfunction
manual defrost key
Short circuit
(sheet key)
CPU board malfunction
E707
Momentally power failure
Commercial power supply stops for 40 to 300msec.
E807
Lower ventilator is opened
Lower ventilator is opened during frozen operation
001-030̲E-SM(LXE10E-1E)A4 2007.04.27 13:29 ページ 28
https://daikin-p.ru
Summary of Contents for LXE10E-1
Page 32: ...31 7 10 7 14 Schematic wiring diagram LXE10E 1E https daikin p ru...
Page 33: ...32 https daikin p ru...
Page 34: ...33 7 11 7 15 Stereoscopic wiring diagram LXE10E 1E https daikin p ru...
Page 35: ...34 https daikin p ru...
Page 49: ...48 2 22 2 5 4 3 12 RSV CSV DEHUMID LED 1 30 RH 95 RH LXE10E 1 LXE10E 1A https daikin p ru...
Page 55: ...54 4 6 1 2 P 4 3 P 3 56 3 L LP HP LXE10E 1 LXE10E 1A LXE10E 1 LXE10E 1A https daikin p ru...
Page 58: ...57 4 18 2 120 248 F EV EV 4 2 5 TEV VTX 3410DMS 1 120 248 F https daikin p ru...
Page 66: ...65 LXE10E 1E 7 10 https daikin p ru...
Page 67: ...66 https daikin p ru...
Page 68: ...67 LXE10E 1E 7 11 https daikin p ru...
Page 69: ...68 https daikin p ru...
Page 105: ...Parts related with option 3 Indoor fanguard K1 TR06 13 104 https daikin p ru...