6-9
Location
Socket No.
Malfunction or Alarm
when the socket is disconnected or loosened.
SMV Board
(EC6)
CN81
(White)
No Alarm······No power supply to Controller
CN82 (Red)
No Alarm······No power supply to Controller
CN83
(Yellow)
F803
CN84 (Blue)
F603
PT/CT
Board (EC6)
CN1
F705
CPU Board
(CN1)
CN15
No Alarm······No communication to cpomputor for data down loading
Terminal
Board
(TB1)
CN2
F101
Terminal
Board
(TB1)
CN6
F803, E401, E403, E409, E411, E413, E415
("E" displayed in SS, RS temperature indication for E401, E403)
Fu5
No Alarm······No power supply to Controller
Terminal
Board
(TB1)
Fu4
F603, E315, E417, E421, E423
F705 E315 E417 E421 E423
No Alarm······No power supply to recorder
No Alarm······No power supply to Controller
Malfunction and Alarm
when the socket is disconnected or loosened.
CN2
I/O Board
(EC2)
CN26
CN13
CN16
No Alarm······No power supply to MODEM
CN18
No Alarm······No "signal" power supply to EV
CN1
E109
→
F109 (F803)
CN3
No Alarm······No power to PCC (No operation)
CN4
No Alarm······No power supply to Controller
CN7
F406 E407 E402 E404
("E" displayed in DRS, DSS, EIS, SGS temperature indication)
Location
Fuse No.
Malfunction or Alarm
when the fuse is broken.
Fu6
No Alarm······No power supply to Monitoring Cirit
Fu1
F101
Fu2
BSV
Fu3
E109
→
F109 (F803)······No power to LSV (LSV close)