10. OPTIONAL FUNCTION SETTING MODE
<Key operation to enter/exit>
I/O ON
I/O
OFF
I/O
Power OFF
Unit OFF
All indication
lights on
(for 3 sec.)
Starting
preparation
(for 18 sec.)
※
1
Current
indication
(Operation state)
Circuit Breaker ON
Circuit Breaker OFF
after setting change
( OFF when no setting changed)
for 3 sec.
※
10
Optional Function Setting
F. PTI
S. PTI
M. CHECK
for 3 sec.
To set the USDA AUTO/ON/OFF and CARGO TEMPERATURE SENSOR
ON/OFF:
Select "OFF (not in use)", "3 (3 USDA probes are in use)", "4 (3 USDA
probes and 1 cargo temperature sensor are in use)", or "AU (AUTO
setting)" on the LED while the LCD displays "USdA".
Whenever the
or
key is pressed, the indication of "OFF" or "3"
or "4" is changed.
Press the
key to determine the setting.
Note: When two USDA probes are connected, the setting will be
determined automatically to "3" (3 USDA probes are in use).
To set the DEHUMIDIFICATION CONTROL:
Select "ON" (conducting dehumidifying with humidity sensor) or "OFF" (conducting no dehumidifying) on
the LED while the LCD indicates "dHU".
Whenever the
or
key is pressed, the indication of "ON" or "OFF" is changed.
Press the
key to determine the setting.
Note : This setting can be changed by
key. (Refer to page 3-12)
M
USDA SENSOR ON/OFF,
CARGO TEMPERATURE
SENSOR ON/OFF SETTING
DEHUMIDIFUCATION
CONTROL ON/OFF
SETTING
S
S
<Key operation in this mode>
Whenever the
key is pressed, the display changes.
Turn the power breaker OFF after the setting.