12. OPTIONAL CONDITION SETTING MODE
<
Key operation to enter/exit
>
<Key operation in this mode>
Whenever the
key is pressed, the indication changes.
Turn the power breaker OFF after the setting.
S
To set the chartless code (D code /H code):
Select "ON" (indication of D/H code) or "OFF" (no indication of D/H code) on
the LED when the LCD displays "CHARTLS".
Whenever the
or
key is pressed, the indication of "ON" or "OFF" is
changed.
Press the
key to determine the setting.
To set the USDA sensor selection:
Select "1" or "2" on the LED when the LCD displays "USdA1/2".
Whenever the
or
key is pressed, the indication of "1" or "2" is changed.
H001
CHARTLESS CODE
INDICATION
SETTING
S
S
USDA SENSOR
1/2 SELECTION
SETTING
S
S
I/O ON
I/O
OFF
I/O
Power OFF
Unit OFF
All indication
lights on
(for 3 sec.)
Starting
preparation
(for 18 sec.)
※
1
Current
indication
(Operation state)
Circuit Breaker ON
Circuit Breaker OFF
after setting change
( OFF when no setting changed)
for 3 sec.
for 3 sec.
for 3 sec.
※
10
※
12
※
11
F. PTI
S. PTI
M. CHECK
Optional
Function
Setting
Basic Function
Setting
Optional
Condition
Setting
for 3 sec.
Press the
key to determine the setting.
H001 code is displayed when the control temperature does not lower by 3 ˚C
or more for every 4 hours in pull-down operation.
Select "1" ˚C ,"2" ˚C ,"3" ˚C ,"4" ˚C ,"5" ˚C or "10" ˚C on the LED when the LCD
displays "H001".
Whenever the
or
key is pressed, the indication of the selection from
"1"˚C to "10" ˚C changes. Press the
key to determine the setting.
Refer to page 3-61.