3-36
3.5 Battery
3.5.1 Specifications
DECOS
3
d controller can use Rechargeable battery. It is not possible to exchange the type of battery
afterwards.
The battery is positioned on CPU & I/O box in controller box.
Rechargeable battery: DAIKIN original rechargeable battery, type: 6N-600AA-2 (Red wire is (
+
), Black wire
is (
−
))
3.5.2 Function
This battery is used without main power supply for the following functions.
1) Display wake up (Refer to section 3.3.2) page 3-11.
Setting/Display the following items on the LCD display.
<Display>
Temperature on the return air sensor
Temperature on the supply air sensor
<Setting change>
Inside temperature, defrosting interval, dehumidifying set (Optional), Unit ON/OFF
2) USDA data log
USDA sensors data log every 1 hour
Note) When the Alkaline battery is equipped, it must be replaced for a new every PTI, when USDA is
used.
3) Trip data log
Trip data; Setting point, Supply air, Return air, Humidity and time is logged every 1 hour after power off
until battery run out. (Min. 3 days)
3.5.3 Battery check
Dry battery: Press
key to confirm the Battery mode workable.
When the power is disconneced.
Rechargeable battery: Press "Battery check meter"
Green: Operatable
Red: Replace battery
S
2) USDA data log
3) Trip data log
1) Display wake up
Rechargeable battery
: Available : Not available
https://daikin-p.ru