8-13
I/O ON
I/O
Power OFF
Unit OFF
All lights on
(for 3 sec.)
Preparation
(for 18 sec.)
Circuit Breaker ON
Circuit Breaker OFF
after setting change
( OFF when no setting changed)
for 3 sec.
for 3 sec.
for 3 sec.
for 3 sec.
CASE 2
CASE 1
CASE 3 (Refer to 3.8.3 of Service manual)
Optional
Function
Setting
Basic
Function
Setting
Optional
Condition
Setting
Container
I.D & Time
Setting
PTI
for 3 sec.
for 3 sec.
DECOS
3
: D (C or B or A)
S
Log. Interval: 30 (or 15 or 60 or 120)
S
REC SEN: ON (or OFF)
S
OC-SET: Sing (or Dual)
S
HP: 10 (or 5)
S
DISP: OFF (or ON)
S
COMP: 100 (or 33)
S
REHEAT: OFF (or ON)
S
FA-SEN: OFF (H or L)
(only for DESCOS
3
d)
Container I.D
S
Controller
Time
CHARTLS: OFF (or ON)
S
USDA 1/2: 2 (or 1)
S
H001~H006
S
d-1
**
~d-2
**
S
C/F : C (or F)
USDA: OFF (or 3 or 4)
S
dHU: OFF (or ON)
S
AUT-INT: ON (or OFF)
S
dHU-CAN: ON (or OFF)
4. Setting flow chart
This configuration setting flow shall be utilized, when
Case 1) Where USDA cool transportation setting, defrosting interval automatic changing function, or
dehumidification control clearing function is required. (Optional function setting)
Case 2) Where an urgent change of container ID to other ID should be made.
(Setting of container ID and calendar)
Case 3) Where a new controller is installed for replacement. (Settings of optional function, basic
function, optional conditions, and input data should be made.)
NOTE 1 : All initial settings are pre-setted, when the unit is delivered.
2 : In case to complete the setting change, CIRCUIT BREAKER shall be turned off
08̲LXE10E-A(09-21) 07.2.19 5:00 PM ページ 8-13