8-33
8.2.9 Valve mode
(Applicable models:LXE10E-A14 and A15(A,AR,B))
*
Reheat coil and humidity sensor (optional) are required.
The valve mode shown below is used for transportation of bulbs. To execute the valve mode, setup of
the controller is required. (See the next page)
In the valve mode operation, "b"is displayed in the first segment of the LED display.
Items shown below can be set up.
1
)
Dehumidification: On/Off
If it is set to "ON", the dehumidification range can be set up from 95% to 60%. (Default: 95%)
2
)
Evaporator fan speed: Alternate operation (alternate operation between High and Low every hour)
High speed, low speed
3
)
Defrost start temperature: From +4˚C to +18˚C, (Default: 5˚C)
08̲LXE10E-A(32-39) 07.2.23 2:15 PM ページ 8-33