3
1-1
1. Introduction
1.1 OPERATION RANGE
Use the units within the following range.
1.2 BASIC NAMES OF COMPONENTS
Ambient temperature range
Inside temperature range
Voltage
Vibration and shock
Operation range
-30˚C to +50˚C (-22˚F to + 122˚F)
-30˚C to +30˚C (-22˚F to + 86˚F)
50Hz: 380V/400V/415V, 60Hz: 440V/460V
Voltage fluctuation rate should be within
±
10%
2G
Item
1
1 2
1 3
6
1 0
4
11
5
9
8
2
3
7
q
Compressor
w
Air-cooled
condenser
e
Receiver
r
Evaporator
t
Control
box
Outside:
switch, manual defrost switch
Inside:
circuit
breaker
y
Condenser
fan
u
Drier
i
Access
panel
o
Storage space for power cable
!0
Ventilator
!1
Sampling port (Return)
Use this port to measure the
inside return air temperature.
!2
Gas sampling port
This is used to measure the
Sampling port (Supply)
inside supply air temperature
and inside CO
2
concentration.
!3
Liquid moisture indicator
03̲LXE10E-A33.indd 3
03̲LXE10E-A33.indd 3
07.2.1 10:52:28 AM
07.2.1 10:52:28 AM
https://daikin-p.ru