5-8
●
Type: 5ZZ2157
Consisting of the body (wire reel and position
meter) and the wire. The top of the wire is
connected to the ventilator outlet cover so that
the ventilator outlet opening can be detected.
Setting method
To validate the ventilator outlet opening
detection function, it is necessary to configure
the settings in accordance with the installation
positions of the ventilator outlet in the "basic
function setting mode" mentioned below
OFF : Detection function not available
H : Detection function available
at the upper ventilator opening
L : Detection function available
at the lower ventilator opening
FA SEN
Make selection using the
key and
key. Press the
key to confirm the selection
LED screen
LCD screen
Setting method
Compressor unloader
system setting
S
Setting of dehumidification
coil available or not available
S
Detection of ventilation amount
(FA log) function setting
11. Basic function setting mode
Set to "H"
Set to "L"
Ventilator
outlet cover
Control box
FA sensor
LED part
LCD part
5.4 Ventilator outlet opening detection
(FA sensor)