CAUTION
Keep the ventilation closed when
ventilation is not necessary or during
transportation of the frozen cargo.
1.3.4 Adjust the ventilation
Adjust the opening of the ventilation
according to the cargo.
"CLOSE"
"OPEN"
Air inlet
Ventilation cover
Handle
Air outlet
Air inlet
Air outlet
Nameplate
Arrow mark
Set the arrow mark of the handle to "CLOSE"
when ventilation is not required or during
frozen operation.
When ventilation is required (chilled mode)
slide the handle upward.
*
Set the arrow mark of the ventilation at the
scale on the nameplate according to the
required ventilation amount.
1-4
◆
Fresh air suction amount
The scale marks on the nameplate are the
reference ones, not guaranteeing the amount.
Fresh air suction amount (ventilation amount)
varies in accordance with static pressure
differences, the container conditions, cargo
loading condition in the container, and power
supply (voltage, frequency).
・
In the case of the same static pressure,
fresh air suction amount at 50 Hz is reduced
to approximately 5/6 of that at 60 Hz.
Nameplate attached to the unit