3-30
3.4.4 Battery replacement (Rechargeable battery)
<How to replace the rechargeable battery>
·
Always turn off the main power supply to the facility before carrying out the following procedures.
(1) Remove the controller and the binding bands
q
~
e
fastening the harnesses and the harness of the
rechargeable battery.
(2) Disconnect connector
r
from the CPU board.
(3) Remove the harness of the rechargeable battery from wire saddle
t
.
(4) Remove Velcro tape
y
and rechargeable battery
u
.
(5) Replace the rechargeable battery with a new one. (Ensure that the battery of the specified type is
used.)
(6) Fix rechargeable battery
u
with Velcro tape
y
used for fixing the battery.
(7) Securely attach the connector to connector
r
on the CPU board. (Refer to Note 1.)
(8) Fix the harness of rechargeable battery
u
and other harnesses to the controller unit with binding band
q
. (Refer to Note 1.)
(9) Pass the harness of rechargeable battery
u
through wire saddle
t
. (Refer to Note 1.)
(10) Bind the harness of rechargeable battery
u
and other harnesses with binding band
w
. (Refer to Note
2.)
(11) Fix the harness of rechargeable battery
u
and other harnesses to the controller unit with binding band
e
. (Refer to Note 2.)
Note 1: Because of the battery property, accurate remaining voltage cannot be obtained if not fully
charged.
Note 2: The remaining voltage during recharging, under the recharger's influence, is indicated (blinking)
higher than it should be.
2) Rechargeable battery
The battery life is approximately 2 years. In the event of using the battery for 2 years or more, data
logging etc. may not be executed when the power is turned off even if the LCD screen indicates that the
remaining voltage is 7.6V or more.
3) The remaining voltage for dry batteries can be checked, but replace the new ones before a voyage as
needed basis such as refrigerated transport (USDA). Don’t judge by the remaining voltage.
Rechargeable battery
⑦
Velcro tape fixing the rechargeable battery
⑥
connector
④
CN48 (BAT)
Binding band
①
Wire saddle
⑤
Binding band
②
Binding band
③
●
Remove the faulty battery and ensure that it is disposed of safely. Refer to next
page for detail.
→
A NiCd battery is used.
●
The battery has to be removed before disposing of the unit.
Attention
Note 1:
Pass the harness of the
rechargeable battery
behind the harnesses
connected to the round
solderless terminal block.
Note 2:
Bind the redundant
portion of the harness of
the rechargeable battery.