3-46
3.7.2.4 Manual check (M.CHECK)
In M. CHECK, each functional component is inspected. However, unlike in S.PTI and F.PTI, there is no
alarm indication etc.
<Inspection items>
Compressor operation time, evaporator fan high-speed operation current, evaporator fan low-speed
operation current, condenser fan operation current, battery lifespan (number of years or months),
horsepower indication, time elapsed since starting the trip, operation time of evaporator fans 1 & 2,
operation time of the condenser fan, and software version
<Control method>
LED screen
LCD screen
Setting method and description
Setting items
Accumulated operation time
of the compressor
Evaporator fan operation
current at high speed
Evaporator fan operation
current at high speed
Evaporator fan operation
current
Time elapsed since starting
the trip
Accumulated operation time
of evaporator fan 1
CC
×
10H
EFH A
The unit is A.
The unit is A.
The unit is A.
EFL A
CF A
TS H
EF1
×
10H
Press the key to display the number
in the LED meaning the accumulated
operation time of the compressor.
Press the key to operate the
evaporator fan at high speed, and the
operation current of the fan is
indicated in the LED.
Press the key to operate the
evaporator fan at low speed, and the
operation current of the fan is
indicated in the LED.
Press the key to operate the
condenser fan, and the operation
current of the fan is indicated in the LED.
Press the key to show the time
elapsed since starting the trip.
Press the key to show the accumulated
operation time of evaporator fan 1 in the LED.
The unit is [hour].
Keep the key pressed for 3
seconds to start the trip with the time
elapsed reset to 0 [hour].
Operation time = Number in LED
×
10 [hours]
Keep the key pressed for 3 seconds to
reset the accumulated operation time to 0.
Operation time = Number in LED
×
10
[hours]
Keep the key pressed for 3 seconds to
reset the accumulated operation time to 0.
Evaporator fan 1 is located on the right
viewed from the inside.
Compressor
accumulated
operation time
Evaporator fan
high-speed
operation current
Evaporator fan
low-speed
operation current
Condenser fan
operation current
Time elapsed
since trip start
Evaporator fan 1
accumulated
operation time
https://daikin-p.ru