Advanced Settings
Function
1
2
3
4
Dust/Particle Sensor
Sensitivity Setting
(Low, Normal, High)
Setting at time of purchase: Normal
The sensitivity setting of the dust/particle
sensor can be changed (Low, Normal, High).
•
“Low” makes the sensor less responsive.
“High” makes the sensor more responsive.
Operation can be performed either
during operation or while operation
is stopped.
Hold down
for about
5 seconds and when a
short beep sounds, press
while pressing
Release both
and
when a short beep
sounds
The FAN lamp corresponding to
the currently set sensitivity will
light up after blinking.
“Low”
“Normal”
“High”
Press
to change the setting*
Each press cycles between “Low”,
“Normal”, “High”.
“Low”
“Normal”
“High”
Press
1 short beep will sound and the set FAN
lamp will blink.
“Low”
“Normal”
“High”
While the lamp is blinking,
unplug the power supply
plug, wait at least
5 seconds, and then insert
the power supply plug
again.
Setting is now complete.
Power supply
plug
Power socket
•
If this procedure is not performed,
the unit will not return to regular
operation mode.
•
Settings are remembered even if the
unit is unplugged.
Monitoring mode within
ECONO MODE (ON/OFF)
Setting at time of purchase: ON
When the fan has stopped in Monitoring mode,
the sensors reduce in sensitivity.
To prevent this reduction in sensitivity, turn
Monitoring mode OFF.
•
If set to OFF, monitoring stops.
Operation can be performed either
during operation or while operation
is stopped.
Hold down
for about
5 seconds and when a
short beep sounds, press
while pressing
Release both
and
when a short beep
sounds
The FAN lamp (Quiet) will light
up after blinking.
[Blinking
→
Lit up]
The ECONO MODE lamp changes as
below according to the current setting.
“ON”
[Blinking
→
Lit up]
“OFF”
[Unlit]
Press
to change the setting*
Each press cycles between “ON” and
“OFF”.
“ON”
[Lit up]
“OFF”
[Unlit]
Press
A short beep sounds and the FAN lamp “Quiet”
blinks, and the ECONO MODE lamp changes
as below according to the current setting.
[Blinking]
“ON”
[Blinking]
“OFF”
[Unlit]
Airflow rate range for AUTO
FAN (4 levels/3 levels)
Setting at the time of purchase: 4 levels
If operating sounds during AUTO FAN MODE
bother you, switch from “4 levels” to “3 levels”.
Airflow rate range
4 levels: “Quiet” “Low” “Standard” “High”
3 levels: “Quiet” “Low” “Standard”
Operation can be performed either
during operation or while operation
is stopped.
Hold down
for about
5 seconds and when a
short beep sounds, press
while pressing
Release both
and
when a short beep
sounds
AUTO FAN MODE lamp will light
up after blinking.
[Blinking
→
Lit up]
According to the current setting, the
FAN lamp will be displayed as follows.
“4 levels”
[Unlit]
“3 levels”
[Blinking
→
Lit up]
Press
to change the setting*
The airflow rate switches between
“4 levels” and “3 levels” with each press.
“4 levels”
[Unlit]
“3 levels”
[Lit up]
Press
A short beep sounds and the AUTO FAN
MODE lamp blinks, and the FAN lamp
changes as below according to the setting.
[Blinking]
“4 levels”
[Unlit]
“3 levels”
[Blinking]
* If the lamps do not change even after the settings were changed, unplug the unit, wait at least 5 seconds, then re-insert the power supply plug
and repeat the above procedure from the beginning.