34
English
Advanced Settings
Function
1
2
3
4
Humidifying Filter Drying
Operation
(ON/OFF)
Setting at the time of purchase: ON
Humidifying filter drying operation is
automatically started when operation is
stopped after Humidifying Operation is
performed in AUTO Operation, MODE
operation, or Humidifying and Air Purifying
Operation.
(This shortens the period when the
humidifying filters are left semi-damp and
bacteria is likely to propagate.)
•
When set to “OFF”, Humidifying Filter Drying
Operation will not be performed.
Setting can be performed either
during operation or while operation
is stopped.
Press
for about
5 seconds, and when a
short beep sounds, press
while continuing
to hold down
.
When a short beep
sounds, release
and
.
The humidifier lamp blinks, then
lights up.
[Blinking
→
Lit up]
According to the current setting,
the FAN lamp will be displayed as
follows.
[Blinking
→
Lit up]
“ON”
[Unlit]
“OFF”
Press
to change the
setting*.
Each press cycles between “ON” and
“OFF”.
[Lit up]
“ON”
[Unlit]
“OFF”
Press
.
A short beep sounds, the humidifier
lamp blinks, and the FAN lamp changes
to the following display according to the
setting.
[Blinking]
[Blinking]
“ON”
[Unlit]
“OFF”
While the lamp is blinking,
unplug the power supply
plug, wait at least
5 seconds, and then insert
the power supply plug
again.
Setting is now complete.
Power supply plug
Power socket
• If this procedure is not performed,
the unit will not return to regular
operation mode.
• The settings will be remembered
even if the power supply plug is
removed.
Airflow rate limit when the
water supply lamp is lit
(Quiet/OFF/Fan stop)
Setting at the time of purchase: Quiet
If you do not want the airflow rate set to
“Quiet” when the water supply lamp is lit, set it
to “OFF”.
When set to “OFF”, even if the water supply
lamp lights up, the airflow rate from before the
lamp lit up continues.
If you are concerned about the odour when the
water supply lamp is lit, set to “Fan stop”.
Setting can be performed either
during operation or while operation
is stopped.
Press
for about
5 seconds, and when a
short beep sounds, press
while continuing
to hold down
.
When a short beep
sounds, release
and
.
The water supply lamp blinks, then
lights up.
[Blinking
→
Lit up]
According to the current setting,
the FAN lamp will be displayed as
follows.
[Blinking
↓
Lit up]
“Quiet”
[Blinking
↓
Lit up]
“OFF”
[Unlit]
“Fan stop”
Press
to change the setting*.
Each press cycles between “Quiet”,
“OFF” and “Fan stop”.
[Lit up]
“Quiet”
[Lit up]
“OFF”
[Unlit]
“Fan stop”
Press
.
A short beep sounds, the water supply
lamp blinks, and the FAN lamp changes
to the following display according to the
setting.
[Blinking]
[Blinking]
“Quiet”
[Blinking]
“OFF”
[Unlit]
“Fan stop”
Notification tone when water
supply lamp is lit
(ON/OFF)
Setting at the time of purchase: ON
If the notification tone emitted when the water
supply lamp is lit bothers you, set it to “OFF”.
• This is a useful function during sleep hours.
•
The error notification alarm cannot be turned off.
Press
for about
3 seconds while
operation is stopped.
Each time
is pressed for
about 3 seconds, the setting
changes.
[Lit up]
“ON”
[Blinking]
“OFF”
The setting is complete
when it blinks or lights up
for about 5 seconds and
then turns off.
* If the lamps do not change even after the settings were changed, unplug the unit, wait at least 5 seconds, then re-insert the power supply plug and
repeat the above procedure from the beginning.
01_EN_3P693798-1B.indd 34