Removal Procedure
SiBE81-909
84
Humidifying Air Purifier
8.6
Removal of Power Supply / Control PCB
Warning
Be sure to wait 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1. Removal of the electric
equipment box cover
Preparation in advance
Remove the display PCB
and the operation PCB.
Refer to the removal of the
display PCB and the
operation PCB.
1
Remove the 5 screws
of the rear panel.
2
Disconnect the
connector for the limit
switch.
3
Remove the 2 screws
of the electric
equipment box cover.
★
The electric equipment box
cover has a drip proof plate.
Fit the slit of the plate to the
rib of the cover, and put the
slit into the crack along the
curve.
(R9822)
The screws in
{
are already
removed
(R9823)
Limit
switch
Holder
(R9824)
Fit the harness to
the groove of the rib
Drip proof plate
Slit
Electric equipment
box cover