4
|
Components
Service manual
154
RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11B – 2022.02
3×
2
2
1
1
1
To remove the top plate
INFORMATION
This procedure is just an example and may differ on some details for your actual unit.
Prerequisite:
Stop the unit operation via the user interface.
1
Turn OFF the respective circuit breaker.
DANGER: RISK OF ELECTROCUTION
Wait for at least 10 minutes after the circuit breaker has been turned OFF, to be sure
the rectifier voltage is below 10 V DC before proceeding.
2
Loosen and remove the screws that fix the top plate.
a
b
a
a
a
a
a
a
Screw
b
Top plate
3
Remove the top plate.
To remove the front plate
INFORMATION
This procedure is just an example and may differ on some details for your actual unit.
Prerequisite:
153].
1
Loosen and remove the screws that fix the front plate.