4
|
Components
Service manual
165
RXM20~71R(9) + ARXM25~71R(9) + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11B – 2022.02
c
f
b
a
d
A
e
A
Class 50~71 unit
a
Power supply terminal X1M
b
Power supply wiring bracket
c
Screw (ground wire)
d
Indoor unit main PCB
e
Switch box screw
f
Switch box
5
Disconnect the connectors of the indoor unit fan motor, the swing flap motor,
the swing raster motor and the streamer unit from the indoor unit main PCB.
6
Detach these wiring harnesses from the switch box.
7
Remove the screw and remove the switch box from the indoor unit.
8
To install the switch box, see
Floor standing indoor units
Prerequisite:
Stop the unit operation via the user interface.
Prerequisite:
Turn OFF the respective circuit breaker.
Prerequisite:
Remove the required plate work, see
1
Disconnect the power supply wiring from the power supply terminal X1M.
2
Remove the screw and power supply wiring bracket.
f
e
f
a
b
c
g
d
a
Power supply terminal X1M
b
Power supply wiring bracket
c
Screw (ground wire)