QTRON Starlite SYSTEM KEYPAD OVERVIEW 

 

 

 

SUMMARY OF KEYPAD OPERATION 
 

Key 

Fast Key (Press & hold for 2s) 

Description 

AUTO 

AUTO HOME Arming 

DAY 

DAY Arming 

NIGHT 

NIGHT Arming

 

FORCE 

FORCE Arming 

AUTOMATION 

AUTOMATION menu

 

MEMORY 

VIEW ALARM MEMORY menu

 

CHIME 

CHIME menu 

SERVICE 

SERVICE menu

 

BYPASS 

BYPASS menu

 

FIRE 

FIRE ALARM

 

EMERGENCY 

EMERGENCY ALARM

 

PANIC 

PANIC ALARM

 

 

Key 

Key Description 

Description 

CANCEL 

Clear the pin number on main menu. 
Exit automation/ memory/ chime/ service/ bypass mode.  

ENTER 

Confirm input/ setting/ pin.  

COM  COMMAND 

Enter User / Installer programming mode.

 

 
 

Summary of Contents for QTRON STARLITE

Page 1: ...Security Home Automation System QTRON STARLITE USER MANUAL REVISION 1 2 ...

Page 2: ...QTRON Starlite User Manual Rev 1 2 ...

Page 3: ...LARM SYSTEM OPERATION CHAPTER 2 TELEPHONY CONTROL FLOW With Voice 2 1 TELEPHONY CONTROL FLOW BEEPER 2 2 SYSTEM ALEART TO USER THROUGH TELEPHONE CHAPTER 3 USER PROGRAMMING 3 1EDIT CONTROL CODE 3 1 1 CHANGE MASTER PIN 3 1 2 ADD CHANGE USER PIN 3 2CHANGE DURESS PIN 3 3SYSTEM S TIME 3 4 TIMER SETTING 3 4 1AUTO ARM TIMER 3 4 2AUTO DISARM TIMER 3 4 3 AUTOMATION I O ON TIMER 3 4 4AUTOMATION I O OFF TIMER...

Page 4: ...GS CHAPTER 5 SYSTEM CHECKING 5 0 CHECK FOR SYSTEM TROUBLE 5 1 TAMPERED AND PHONE LINE LOSS ALARM INDICATION 5 2 SYSTEM TESTING 5 2 1 WALK TEST 5 2 2 CMS TEST 5 2 3 SIREN TEST 5 2 4 STROBE LIGHT TEST 5 2 5 BATTERY TEST GLOSSARY SYSTEM INFORMATION 13 14 15 15 15 16 16 16 16 16 16 17 18 ...

Page 5: ...rough unprotected openings or have the technical sophistication to bypass an alarm sensor or disconnect an alarm warning device Intrusion detectors smoke detectors and many sensing devices will not operate without power Devices powered by AC will not work if there is no AC power supply for any reason and their back up batteries are missing dead or improperly installed Alarm warning devices such as...

Page 6: ... Normally Open NO Normally Close NC 14 Adjustable loop response sensitivity 15 Key Switch function Latch Momentary 16 Dedicated Tamper zone 17 AC power supply monitoring 18 Low battery indication 19 Bell Test Walk Test function 20 Telephone line loss detection 21 Telephone Voice Module 22 RS485 ready to support longer distance communication 23 Report events to 4 phone numbers with 4 account number...

Page 7: ...FORCE FORCE Arming 5 AUTOMATION AUTOMATION menu 6 MEMORY VIEW ALARM MEMORY menu 7 CHIME CHIME menu 8 SERVICE SERVICE menu 9 BYPASS BYPASS menu F FIRE FIRE ALARM E EMERGENCY EMERGENCY ALARM P PANIC PANIC ALARM Key Key Description Description CANCEL Clear the pin number on main menu Exit automation memory chime service bypass mode ENTER Confirm input setting pin COM COMMAND Enter User Installer prog...

Page 8: ...armed instantly while user stays at home The interior zones are automatically bypassed and the delay zones become instant zone When everyone come back to home user want to sleep Force Arming To force arm the system with Exit delay count down in order for the user to exit the house The interior zones are not bypassed When there are zones faulty SOUND INDICATION Sound Indication Description Acceptan...

Page 9: ... 0 1 second OFF No Description PWR ARM SER KEY MEM Zones 1 Normal Mode OFF OFF Zone status 2 Arming ON OFF Zone status 3 Home Automation Mode Flash OFF Flash OFF OFF IO status 4 User Programming Mode OFF Flash Flash Flash Flash 5 AC power failure OFF ON OFF 6 Service status ON OFF 7 View Service Mode Flash OFF ON according to the type of trouble refer to table below 8 Zone s Status Opened Bypassed...

Page 10: ... OFF AUTOMATION Press and hold 5 for 2 second 1 to 8 VIEW ALARM MEMORY Press and hold 6 for 2 second PROGRAM CHIME ZONE Press and hold 7 for 2 second VIEW SERVICE MODE Press and hold 8 for 2 second BYPASS ZONE Press and hold 9 for 2 second Zone 1 to 8 FIRE ALARM Press and hold F for 2 second EMERGENCY ALARM Press and hold E for 2 second PANIC ALARM Press and hold P for 2 second Default Master Pin ...

Page 11: ...em Status 3 for Siren Control 4 for Zone Bypass Restore Menu 5 for Automation Menu Press 0 for Exit 3 ON OFF Siren 4 Zone Bypass Byp ass Restore 01 to 08 Zone Number to exit 2 System Status Report On System Arm Disarm Alarm Triggered Zone Zone Open Bypassed Siren ON OFF Output ON OFF DC Siren AC Status if system status enabled Fire Emergency Panic alarmed 5 On Off Automation Output 01 to 08 Output...

Page 12: ...eep Continuous tone for Alarm OR 5 beep tone for Arm Disarm Zone Restore Trouble Answer Call Slow beeps Press any key 0 9 Alarm Event Tone To Force Arm System 1 0 To Disarm System 2 0 To Check Alarm report 3 For next alarm press again To ON Siren 4 To OFF Siren 5 To Bypass Zone 6 Zone Number 01 08 To Restore Bypass Zone 7 Zone Number 01 08 To ON Automation output 8 Output Number 00 08 To OFF Autom...

Page 13: ...dition no voice or beeper reporting and voice reporting if voice module is installed System will report the status of the system to user when an event happened accordingly to the list below Reporting Through Telephone Description Zone X Violated Zone X has been violated Zone X Restored Alarm in zone X has been restored Emergency Emergency button had been pressed Fire Fire button had been pressed P...

Page 14: ...10 Current Time 24 Hour Format AUTO ARM TIMER Press 11 Auto Arm Timer AUTO DISARM TIMER Press 12 Auto Disarm Timer ON IO TIMER 1 Press 13 Auto On Timer 1 OFF IO TIMER 1 Press 14 Auto Off Timer 1 ON IO TIMER 2 Press 15 Auto On Timer 2 OFF IO TIMER 2 Press 16 Auto Off Timer 2 TELEPHONE NUMBER 1 Press 17 Phone Number 1 TELEPHONE NUMBER 2 Press 18 Phone Number 1 TELEPHONE NUMBER 3 Press 19 Phone Numbe...

Page 15: ...n only arm unarm in away arm mode 3 2 CHANGE DURESS PIN Note Duress Code default value 2222 3 3 SYSTEM S TIME This allow user to edit the time of the system Command Information Press 10 then set the current time in 24 hour format and press after done The keypad will sound 2 fast beeps after pressing 10 then keypad will sound another 2 fast beeps after the new time was set Command Information Press...

Page 16: ...keypad will sound another 2 fast beeps after the auto disarm timer was set To delete the timer press 12 then 12 The keypad will sound 2 fast beeps after pressing 12 then keypad will sound another 2 fast beeps after delete the timer 3 4 3 AUTOMATION I O ON TIMER It is to set the timer to turn ON the outputs automatically Command Information Press 13 then set the timer 1 to turn on the outputs in 24...

Page 17: ...ypad will sound another 2 fast beeps after delete the timer Command Information Press 17 then set the telephone number 1 for CMS system The keypad will sound 2 fast beeps after pressing 17 then keypad will sound another 2 fast beeps after the telephone number 1 was set Press 18 then set the telephone number 2 for CMS system The keypad will sound 2 fast beeps after pressing 18 then keypad will soun...

Page 18: ...plied to that individual keypad Remark Keypad Back Light The light which light up the keypad button area Entry Exit Delay Buzzer Sound The beeps sound during entry and exit delay Lock Unlock Keypad A function that prevent stranger interrupt the system Functions Command Information Keypad Backlight Press COM 6 This operation will toggle the keypad back light to ON OFF ENTRY EXIT DELAY BUZZER SOUND ...

Page 19: ...ce light will be ON if the trouble conditions still remain The designated zone light will be restored back to the actual zone s status The following are the system service indication represented by the Zone s LED 5 1 TAMPEREDANDPHONELINE LOSS ALARM INDICATION Reporting Zone indication Description Tampered Alarm ARMED and all zone LED will fast Blinkto indicate the alarm was triggered by the tamper...

Page 20: ...ime zone faulted corresponding zone light will fast flash and keypad will chime until system exit walk test To exit press key The keypad will beep twice upon confirmation Back to normal mode 5 2 2 CMS TEST Command Information Manual test reporting for CMS Press COM 2 The keypad will beep twice upon confirmation Panel will generate message to CMS center 5 2 3 SIREN TEST Command Information Test sir...

Page 21: ...toring station CMS Default duress code is 2222 Entry Delay The amount of time that you are allowed to enter the premises when the system is armed Exit Delay The amount of time that you are allowed to leave the premises when the system is arming User Pin A four digit pin which can be used to arm and disarm the system from the keypad They are total maximum 7 user code can be set Master Pin A four di...

Page 22: ...ne Number 2 Receiver Number 2 Receiver Type User CMS Receiver Pattern Permanent Backup CMS Account Number 2 Telephone Number 3 Receiver Number 3 Receiver Type User CMS Receiver Pattern Permanent Backup CMS Account Number 3 Telephone Number 4 Receiver Number 4 Receiver Type User CMS Receiver Pattern Permanent Backup CMS Account Number 4 Telephony Settings Dial Attempt times Redial Attempt times Num...

Page 23: ...ior Instant Delay 24 Hours Yes No 6 Light Interior Instant Delay 24 Hours Yes No 7 Light Interior Instant Delay 24 Hours Yes No 8 Light Interior Instant Delay 24 Hours Yes No Output Settings Output Output Description 1 2 3 4 5 6 7 8 Output Timers Timer Timer ON Timer OFF Output No Timer 1 Date Time Date Time Timer 2 Date Time Date Time Arm Disarm Timers Timer Timer ARM Timer DISARM Timer 1 Date Ti...

Page 24: ...QTRON Starlite User Manual Rev 1 2 ...

Page 25: ......

Reviews: