Specifications 60Hz 230V
EDUS04-906
4
Room Air Conditioners H-Series
3. Specifications
60Hz 230V
Note:
The data are based on the conditions shown in the table below.
Models
Indoor Units
FTXG09HVJU
FTXG12HVJU
Outdoor Units
RXG09HVJU
RXG12HVJU
Cooling
Heating
Cooling
Heating
Capacity
Rated (Min.~Max.)
Btu/h
9,000 (5,300~12,300)
12,000 (4,400~18,000)
12,000 (5,300~15,700)
16,000 (4,400~19,100)
Moisture Removal
Pt/h
3.3
—
4.1
—
Running Current (Rated)
A
3.10
4.04
4.30
5.64
Power Consumption Rated (Min.~Max.)
W
570 (250~900)
780 (220~1,900)
860 (260~1,300)
1,160 (220~2,100)
Power Factor
%
80.0
84.0
87.0
89.5
EER (Rated)
Btu/h·W
15.8
—
14.0
—
COP (Rated)
W/W
4.6
4.5
4.1
4.0
Energy
Efficiency
SEER/HSPF
22.0
11.0
22.0
10.6
Piping
Connections
Liquid
inch (mm)
φ
1/4” (6.4 mmm)
φ
1/4” (6.4 mmm)
Gas
inch (mm)
φ
3/8” (9.5 mm)
φ
3/8” (9.5 mm)
Drain
inch (mm)
φ
11/16” (17.5 mm)
φ
11/16” (17.5 mm)
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Max. Interunit Piping Length
feet (m)
32 ft (10 m)
32 ft (10 m)
Max. Interunit Height Difference
feet (m)
26 ft (8 m)
26 ft (8 m)
Chargeless
feet (m)
—
—
Amount of Additional Charge of
Refrigerant
oz/ft
—
—
Indoor Units
FTXG09HVJU
FTXG12HVJU
Front Panel Color
White
White
Airflow Rate
cfm (m³/min)
H
420 (11.9)
438 (12.4)
459 (13.0)
470 (13.3)
M
325 (9.2)
346 (9.8)
346 (9.8)
367 (10.4)
L
230 (6.5)
258 (7.3)
240 (6.8)
272 (7.7)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
57
57
Speed
Steps
5 Steps, Quiet and Auto
5 Steps, Quiet and Auto
Air Direction Control
Right, Left, Horizontal and Downward
Right, Left, Horizontal and Downward
Air Filter
Removable / Washable / Mildew Proof
Removable / Washable / Mildew Proof
Running Current (Rated)
A
0.12
0.14
0.14
0.15
Power Consumption (Rated)
W
24
26
29
31
Power Factor
%
87
80.7
90.1
89.9
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H×W×D)
inch (mm)
12 × 35-1/16 × 8-1/4” (305 x 891 x 210 mm)
12 × 35-1/16 × 8-1/4” (305 x 891 x 210 mm)
Packaged Dimensions (H×W×D)
inch (mm)
11 × 37-5/8 × 14-7/8” (279 x 956 x 378 mm)
11 × 37-5/8 × 14-7/8” (279 x 956 x 378 mm)
Weight
Lbs (kg)
31 lbs (14 kg)
31 lbs (14 kg)
Gross Weight
Lbs (kg)
38 lbs (17 kg)
38 lbs (17 kg)
Operation Sound
H/M/L
dBA
42 / 33 / 26
42 / 35 / 28
43 / 35 / 27
43 / 36 / 29
Outdoor Units
RXG09HVJU
RXG12HVJU
Casing Color
Ivory White
Ivory White
Compressor
Type
Hermetically Sealed Swing Type
Hermetically Sealed Swing Type
Model
2YC36CXD
2YC36CXD
Motor Output
W
1,100
1,100
Refrigerant
Oil
Type
FVC50K
FVC50K
Charge
oz
13.5
13.5
Refrigerant
Type
R-410A
R-410A
Charge
Lbs
3.1
3.1
Airflow Rate
cfm (m³/min)
H
1,178 (33.4)
1,095 (31.0)
1,262 (35.7)
1,111 (31.5)
L
—
—
—
—
Fan
Type
Propeller
Propeller
Motor Output
W
60
60
Running Current (Rated)
A
2.98
3.9
4.16
5.49
Power Consumption (Rated)
W
546
754
831
1,129
Power Factor
%
79.7
84.1
86.9
89.4
Dimensions (H×W×D)
inch (mm)
22-3/8 × 31-5/16 ×11-1/4”
(568 x 795 x 286 mm)
22-3/8 × 31-5/16 ×11-1/4”
(568 x 795 x 286 mm)
Packaged Dimensions (H×W×D)
inch (mm)
25-3/16 ×36-7/16 ×14-7/8”
(568 x 795 x 286 mm
25-3/16 ×36-7/16 ×14-7/8”
(568 x 795 x 286 mm)
Weight
Lbs(kg)
99 lbs (45 kg)
99 lbs (45 kg)
Gross Weight
Lbs(kg)
104 lbs (32 kg)
104 lbs (32 kg)
Operation
Sound
H / L
dBA
46 / —
46 / —
49 / —
48 / —
Drawing No.
3D062857
3D062858
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling
Heating
Piping Length
Indoor ; 80°FDB/67°FWB
Outdoor ; 95°FDB/75°FWB
Indoor ; 70°FDB/60°FWB
Outdoor ; 47°FDB/43°FWB
25ft (7.5 m)
Summary of Contents for Quaternity FTXG09HVJU
Page 1: ...EDUS04 906_a H Series Heat Pump...
Page 44: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 43 Ground terminal...
Page 45: ...Operation Manual EDUS04 906 44 Room Air Conditioners H Series DRY button...
Page 46: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 45...
Page 47: ...Operation Manual EDUS04 906 46 Room Air Conditioners H Series...
Page 48: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 47...
Page 50: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 49...
Page 51: ...Operation Manual EDUS04 906 50 Room Air Conditioners H Series...
Page 52: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 51...
Page 55: ...Operation Manual EDUS04 906 54 Room Air Conditioners H Series...
Page 56: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 55 1 8 F 1 C 3 6 F 2 C...
Page 57: ...Operation Manual EDUS04 906 56 Room Air Conditioners H Series...
Page 58: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 57 COOLING or DRY COOLING mode or...
Page 59: ...Operation Manual EDUS04 906 58 Room Air Conditioners H Series...
Page 60: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 59...
Page 61: ...Operation Manual EDUS04 906 60 Room Air Conditioners H Series...
Page 62: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 61...
Page 63: ...Operation Manual EDUS04 906 62 Room Air Conditioners H Series...
Page 64: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 63...
Page 65: ...Operation Manual EDUS04 906 64 Room Air Conditioners H Series...
Page 66: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 65...
Page 67: ...Operation Manual EDUS04 906 66 Room Air Conditioners H Series...
Page 68: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 67...
Page 69: ...Operation Manual EDUS04 906 68 Room Air Conditioners H Series...
Page 70: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 69 3P226009 1...
Page 79: ...Optional Accessories EDUS04 906 78 Room Air Conditioners H Series...