EDUS04-906
Specifications 60Hz 230V
Room Air Conditioners H-Series
5
60
Hz
230V
Note:
The data are based on the conditions shown in the table below.
Model
Indoor Units
FTXG15HVJU
Outdoor Units
RXG15HVJU
Cooling
Heating
Capacity
Rated (Min.~Max.)
Btu/h
15,000 (5,300~18,000)
18,000 (4,400~21,200)
Moisture Removal
Pt/h
4.8
—
Running Current (Rated)
A
5.64
6.36
Power Consumption Rated (Min.~Max.)
W
1,160 (260~1,930)
1,320 (230~2,120)
Power Factor
%
89.0
99.0
EER (Rated)
Btu/h·W
12.9
—
COP (Rated)
W/W
3.8
4.0
Energy
Efficiency
SEER/HSPF
21.0
10.0
Piping
Connections
Liquid
inch (mm)
φ
1/4” (6.4 mmm)
Gas
inch (mm)
φ
3/8” (9.5 mm)
Drain
inch (mm)
φ
11/16” (17.5 mm)
Heat Insulation
Both Liquid and Gas Pipes
Max. Interunit Piping Length
feet (m)
32’ (10 m)
Max. Interunit Height Difference
feet (m)
26’ (8 m)
Chargeless
feet (m)
—
Amount of Additional Charge of Refrigerant
oz/ft
—
Indoor Unit
FTXG15HVJU
Front Panel Color
White
Airflow Rate
cfm (m³/min)
H
487 (13.8)
494 (14.0)
M
371 (10.5)
392 (11.1)
L
258 (7.3)
293 (8.3)
Fan
Type
Cross Flow Fan
Motor Output
W
57
Speed
Steps
5 Steps, Quiet, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Air Filter
Removable / Washable / Mildew Proof
Running Current (Rated)
A
0.15
0.16
Power Consumption (Rated)
W
33
35
Power Factor
%
95.7
95.1
Temperature Control
Microcomputer Control
Dimensions (H×W×D)
inch (mm)
12 × 35-1/16 × 8-1/4” (305 x 891 x 210 mm)
Packaged Dimensions (H×W×D)
inch (mm)
11 × 37-5/8 × 14-7/8” (279 x 956 x 378 mm)
Weight
Lbs(kg)
31 lbs (14 kg)
Gross Weight
Lbs(kg)
38 lbs (17 kg)
Operation
Sound
H/M/L
dBA
45 / 37 / 29
44 / 38 / 31
Outdoor Unit
RXG15HVJU
Casing Color
Ivory White
Compressor
Type
Hermetically Sealed Swing Type
Model
2YC36CXD
Motor Output
W
1,100
Refrigerant
Oil
Model
FVC50K
Charge
oz
13.5
Refrigerant
Model
R-410A
Charge
Lbs
3.1
Airflow Rate
cfm (m³/min)
H
1,262 (35.7)
1,195 (33.8)
L
—
—
Fan
Type
Propeller
Motor Output
W
60
Running Current (Rated)
A
5.49
6.2
Power Consumption (Rated)
W
1,127
1,285
Power Factor
%
89.3
90.1
Dimensions (H×W×D)
inch (mm)
22-3/8 × 31-5/16 ×11-1/4”
(568 x 795 x 286 mm)
Packaged Dimensions (H×W×D)
inch (mm)
25-3/16 ×36-7/16 ×14-7/8”
(568 x 795 x 286 mm)
Weight
Lbs (kg)
99
Gross Weight
Lbs(kg)
104
Operation
Sound
H / L
dBA
50 / —
50 / —
Drawing No.
3D062859
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling
Heating
Piping Length
Indoor ; 80°FDB/67°FWB
Outdoor ; 95°FDB/75°FWB
Indoor ; 70°FDB/60°FWB
Outdoor ; 47°FDB/43°FWB
25 ft (7.5 m)
Summary of Contents for Quaternity FTXG09HVJU
Page 1: ...EDUS04 906_a H Series Heat Pump...
Page 44: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 43 Ground terminal...
Page 45: ...Operation Manual EDUS04 906 44 Room Air Conditioners H Series DRY button...
Page 46: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 45...
Page 47: ...Operation Manual EDUS04 906 46 Room Air Conditioners H Series...
Page 48: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 47...
Page 50: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 49...
Page 51: ...Operation Manual EDUS04 906 50 Room Air Conditioners H Series...
Page 52: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 51...
Page 55: ...Operation Manual EDUS04 906 54 Room Air Conditioners H Series...
Page 56: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 55 1 8 F 1 C 3 6 F 2 C...
Page 57: ...Operation Manual EDUS04 906 56 Room Air Conditioners H Series...
Page 58: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 57 COOLING or DRY COOLING mode or...
Page 59: ...Operation Manual EDUS04 906 58 Room Air Conditioners H Series...
Page 60: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 59...
Page 61: ...Operation Manual EDUS04 906 60 Room Air Conditioners H Series...
Page 62: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 61...
Page 63: ...Operation Manual EDUS04 906 62 Room Air Conditioners H Series...
Page 64: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 63...
Page 65: ...Operation Manual EDUS04 906 64 Room Air Conditioners H Series...
Page 66: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 65...
Page 67: ...Operation Manual EDUS04 906 66 Room Air Conditioners H Series...
Page 68: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 67...
Page 69: ...Operation Manual EDUS04 906 68 Room Air Conditioners H Series...
Page 70: ...EDUS04 906 Operation Manual Room Air Conditioners H Series 69 3P226009 1...
Page 79: ...Optional Accessories EDUS04 906 78 Room Air Conditioners H Series...