background image

Table of Contents

Installation manual

4

8T7V1B*

VRV IV heat exchanger unit for indoor installation

4P408444-1B – 2016.04

Table of Contents

1 About the documentation

4

1.1

About this document..................................................................

4

2 About the box

4

2.1

Heat exchanger unit ..................................................................

4

2.1.1

To remove the accessories from the heat exchanger
unit ..............................................................................

4

2.1.2

To remove the transportation sheet ............................

4

3 About the units and options

5

3.1

About the compressor unit and heat exchanger unit.................

5

3.2

System layout ............................................................................

5

3.3

Combining units and options .....................................................

5

3.3.1

Possible options for the compressor unit and heat
exchanger unit ............................................................

5

4 Preparation

5

4.1

Preparing installation site ..........................................................

5

4.1.1

Installation site requirements of the heat exchanger
unit ..............................................................................

5

4.2

Preparing electrical wiring .........................................................

6

4.2.1

Safety device requirements ........................................

6

5 Installation

6

5.1

Opening the units ......................................................................

6

5.1.1

To open the switch box cover of the heat exchanger
unit ..............................................................................

6

5.2

Mounting the heat exchanger unit .............................................

6

5.2.1

Guidelines when installing the heat exchanger unit....

6

5.2.2

Guidelines when installing the ducting........................

6

5.2.3

Guidelines when installing the drain piping.................

7

5.3

Connecting the refrigerant piping ..............................................

8

5.3.1

To connect the refrigerant piping to the heat
exchanger unit ............................................................

8

5.4

Connecting the electrical wiring.................................................

8

5.4.1

Field wiring: Overview.................................................

8

5.4.2

Guidelines when connecting the electrical wiring .......

9

5.4.3

To connect the electrical wiring on the heat
exchanger unit ............................................................

9

6 Technical data

9

6.1

Wiring diagram: Heat exchanger unit ........................................

10

1

About the documentation

1.1

About this document

Target audience

Authorised installers

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry  and  on  farms,  or  for
commercial use by lay persons.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you must read before installing

▪ Format: Paper (in the accessory bag of the compressor unit)

Compressor unit installation and operation manual:

▪ Installation and operation instructions

▪ Format: Paper (in the accessory bag of the compressor unit)

Heat exchanger unit installation manual:

▪ Installation instructions

▪ Format:  Paper  (in  the  accessory  bag  of  the  heat  exchanger

unit)

Installer and user reference guide:

▪ Preparation  of  the  installation,  technical  specifications,

reference data,…

▪ Detailed  step-by-step  instructions  and  background  information

for basic and advanced usage

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

2

About the box

2.1

Heat exchanger unit

2.1.1

To remove the accessories from the heat
exchanger unit

b

c

d

a

e

f

g

a

Optional filter for debris

b

Heat exchanger unit installation manual

c

Sealing pad

d

Drain hose

e

Metal clamp

f

Screw (for shield of transmission wiring) (see 

"5.4.3 To

connect the electrical wiring on the heat exchanger unit" on
page 9

)

g

Cable tie

2.1.2

To remove the transportation sheet

Remove the sheet. The sheet protects the unit during transport.

Summary of Contents for RDXYQ8T7V1B

Page 1: ...Installation manual VRV IV heat exchanger unit for indoor installation English Installation manual VRV IV heat exchanger unit for indoor installation RDXYQ5T7V1B RDXYQ8T7V1B...

Page 2: ...iten befinden sich entsprechend Artikel 1 2f des PED au erhalb der Reichweite Risikoart H Siehe auch n chste Seite tel que d fini dans A et valu positivement par B conform ment au Certificat C tel que...

Page 3: ...stysl mp tila M C Kylm aine N Varmuuspainelaitteen asetus P bar Valmistusnumero ja valmistusvuosi katso mallin nimikilpi Maxim ln p pustn tlak PS K bar Minim ln maxim ln p pustn teplota TS TSmin Minim...

Page 4: ...arget audience Authorised installers INFORMATION This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial use by lay persons Documenta...

Page 5: ...ing units and options 3 3 1 Possible options for the compressor unit and heat exchanger unit For more possible options see the installer and user reference guide Drain pan heater EKDPH1RDX When Instal...

Page 6: ...unit and all indoor units and between compressor unit and heat exchanger unit 600 m If the total transmission wiring exceeds these limits it may result in communication error 5 Installation 5 1 Openin...

Page 7: ...Discharge ducting 5 2 3 Guidelines when installing the drain piping Make sure condensation water can be evacuated properly This involves General guidelines Connecting the drain piping to the heat exc...

Page 8: ...NG 5 3 1 To connect the refrigerant piping to the heat exchanger unit 1 Remove the cover 2 Remove the 2 insulation pieces 3 Put a wet cloth in front of the EPS to protect the drain pan 4 Braze the liq...

Page 9: ...F2 F1 F2 F1 F2 b X2M X2M X2M X1M A1P RKXYQ5 RDXYQ5 TO OUT D TO IN D F1 F2 F1 F2 a1 a2 a2 a F1 F2 F1 F2 F1 F2 F1 F2 F1 F2 F1 F2 F1 F2 F1 F2 F1 F2 b a RKXYQ8 RDXYQ8 TO OUT D TO IN D F1 F2 F1 F2 8 HP 5...

Page 10: ...iring depending on model PCB Legend for wiring diagram 5 8 HP A1P Printed circuit board main A2P Printed circuit board adapter C1 Capacitor A1P E1H Drain pan heater optional F1U Fuse F 1 A 250 V optio...

Page 11: ......

Page 12: ...4P408444 1 B 0000000 4P408444 1B 2016 04 Copyright 2015 Daikin...

Reviews: