Following Symptoms are not Air Conditioner Troubles
Si39-406
210
Operation Manual
7. Following Symptoms are not Air Conditioner
Troubles
7.1
The System does not Operate
The air conditioner does not start immediately after the ON/OFF button on the remote
controller is pushed.
If the operation lamp lights, the system is in normal condition.
To prevent overloading of the compressor motor, the air conditioner starts 5 minutes after it is
turned ON again in case it was turned OFF just before. The same starting delay occurs after the
operation mode selector button was used.
If “Centralized Control” is displayed on the remote controller and pressing the operation
button causes the display to blink for a few seconds.
This indicates that the central device is controlling the unit.
The blinking display indicates that the remote controller cannot be used.
The system does not start immediately after the power supply is turned on.
Wait one minute until the micro computer is prepared for operation.
7.2
Cool/heat cannot be Changed Over
When the display shows
“
”
(changeover under control), it shows that this is a
slave remote controller.
When the cool/heat changeover remote control switch is installed and the display shows
“
”
(changeover under control).
This is because cool/heat changeover is controlled by the cool/heat changeover remote control
switch. Ask your Daikin dealer where the remote control switch is installed.
7.3
Fan Operation is Possible, but Cooling and Heating do not
Work
Immediately after the power is turned on.
The micro computer is getting ready to operate. Wait 10 minutes.
7.4
The Fan Strength does not Correspond to the Setting
The fan strength does not change even if the fan strength adjustment button in pressed.
During heating operation, when the room temperature reaches the set temperature, the outdoor
unit goes off and the indoor unit changes to whisper fan strength.
This is to prevent cold air blowing directly on occupants of the room.
The fan strength will not change even if the button is changed, when another indoor unit is in
heating operation.
7.5
The Fan Direction does not Correspond to the Setting
The fan direction does not correspond to the remote controller display.
The fan direction does not swing.
This is because the unit is being controlled by the micro computer.
Summary of Contents for REYQ96MTJU
Page 1: ...Design Installation Testing Instruction R410A Heat Recovery 60Hz REYQ96MTJU Si39 406...
Page 6: ...Si39 406 iv Table of Contents...
Page 34: ...Installation Si39 406 28 General Information Flaring Procedure...
Page 68: ...Installation Si39 406 62 General Information Caution Caution label 3P124617 4P124614...
Page 114: ...Appendix Si39 406 108 General Information 3P135887 1...
Page 126: ...Appendix Si39 406 120 General Information 7 8 3 BS Unit BSVQ36MVJ BSVQ60MVJ 4D045338...
Page 128: ...Appendix Si39 406 122 General Information 7 9 2 Field Wiring REYQ96MTJU 3D042647A...
Page 156: ...Refrigerant Piping Si39 406 150 Installation Manual REYQ96MTJU...
Page 158: ...Refrigerant Piping Si39 406 152 Installation Manual REYQ96MTJU...
Page 230: ...Precautions for New Refrigerant R410A Si39 406 224 Precautions for New Refrigerant R410...
Page 236: ...375 Park Avenue Suite 3308 New York N Y 10152 info daikinac com www daikinac com...