Drain piping connections
Do not connect the drain piping directly to sewage pipes that smell of ammonia. The ammonia in
the sewage might enter the indoor unit through the drain pipes and corrode the heat exchanger.
2
After piping work is finished, check if drainage flows smoothly.
Add approximately 67oz (2000 cc) of water slowly from the air outlet and check drainage flow.
WHEN ELECTRIC WIRING WORK IS FINISHED
Check drainage flow during COOL running, explained under ‘‘TEST OPERATION’’.
WHEN ELECTRIC WIRING WORK IS NOT FINISHED
Remove the terminal box lid connect a power supply and remote controller to the terminals.
(Refer to the Installation Manual)
Next, press the inspection/test operation button “
” on the remote controller. The unit will engage the
test operation mode. Press the operation mode selector button “
” until selecting FAN OPERATION
“
”. Then, press the ON/OFF button “
”. The indoor unit fan and drain pump will start up. Check
that the water has brained from the unit. Press “
” to go back to the first mode.
Note that the fan also starts rotating.
Attach the terminal box lid as before.
TEST
TEST
n
n
n
n
n
The water inlet lid
Drain pipe
Portable pump
Inspection
opening
Service condensate outlet
(with rubber plug)
(Use this outlet to condensate
water from the drain pan)
Bucket
(Adding water from
inspection opening)
Plastic watering can
(Tube should be about
3 15/16" long.)
3 15/16" or more
〈
Adding water through air discharge outlet
〉
[Method of adding water]
208V–230V
Single phase
power supply
Power supply
terminal block
Indoor unit
PC board
Electric parts
box lid (1)
Electric parts
box lid (2)
Power supply
terminal block
Summary of Contents for REYQ96MTJU
Page 1: ...Design Installation Testing Instruction R410A Heat Recovery 60Hz REYQ96MTJU Si39 406...
Page 6: ...Si39 406 iv Table of Contents...
Page 34: ...Installation Si39 406 28 General Information Flaring Procedure...
Page 68: ...Installation Si39 406 62 General Information Caution Caution label 3P124617 4P124614...
Page 114: ...Appendix Si39 406 108 General Information 3P135887 1...
Page 126: ...Appendix Si39 406 120 General Information 7 8 3 BS Unit BSVQ36MVJ BSVQ60MVJ 4D045338...
Page 128: ...Appendix Si39 406 122 General Information 7 9 2 Field Wiring REYQ96MTJU 3D042647A...
Page 156: ...Refrigerant Piping Si39 406 150 Installation Manual REYQ96MTJU...
Page 158: ...Refrigerant Piping Si39 406 152 Installation Manual REYQ96MTJU...
Page 230: ...Precautions for New Refrigerant R410A Si39 406 224 Precautions for New Refrigerant R410...
Page 236: ...375 Park Avenue Suite 3308 New York N Y 10152 info daikinac com www daikinac com...