Electrical box
Si001416E
6
Removal Procedure
3. Electrical box
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Disconnect the
connector [S20] and
pull out the clamp.
[S20]: electronic expansion
valve coil
2
Cut the clamp and
disconnect the
connector [S40].
[S40]: overload protector
3
Disconnect the relay
connector for
compressor.
Clamp
[S20]
(R21297)
[S40]
Clamp
(R21298)
Relay
connector
(R21299)