Thermistor ASSY
Si001416E
14
Removal Procedure
6. Thermistor ASSY
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
2
3
Pull out the discharge
pipe temperature
thermistor.
Cut the clamp.
Pull out the outdoor
heat exchanger
thermistor and remove
the thermistor ASSY.
Be careful not to lose the
fixture for the thermistor.
Be careful not to lose the clip
for the thermistor.
Discharge pipe
temperature
thermistor
Clamp
Outdoor heat
exchanger thermistor
(R21321)
Thermistor ASSY
(R21322)
Fixture
(R20430)
Clip
(R20852)