Removal of PCBs
Si001067
14
Removal Procedure
3. Removal of PCBs
Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure
Points
1. Remove the main PCB
and the forced operation
button PCB.
You can remove the main
PCB when you disconnect
the lead wires on the
terminal board without
removing the electrical box.
1
Layout of the main PCB
2
Remove the screw on
the terminal board.
3
Release the 2 earth
wires.
(R13506)
Main PCB
Forced operation
button PCB
(R11854)
Terminal
board
(R17020)
Earth
wire