Main Functions
SiUS041829E
30
Part 4 Functions and Control
1.8 NIGHT SET Mode
Outline
When the OFF TIMER is set, NIGHT SET mode is automatically activated. NIGHT SET mode
keeps the airflow rate setting.
Details
NIGHT SET mode continues operation at the target temperature for the first one hour, then
automatically raises the target temperature slightly in the case of cooling, or lowers the target
temperature slightly in the case of heating. This prevents excessive cooling in summer and
excessive heating in winter to ensure comfortable sleeping conditions, and also conserves
electricity.
Cooling
Heating
(R23917)
Target temperat
u
re
+0.5°C (+0.9°F)
temperat
u
re shift
Operation stops
at the set ho
u
r
0.5°C (0.9°F)
1 ho
u
r
TIMER operation
NIGHT SET Mode ON
Target temperat
u
re
–2°C (–3.6°F)
temperat
u
re shift
1 ho
u
r
2°C (3.6°F)
(R23918)
TIMER operation
NIGHT SET Mode ON
Summary of Contents for RX09RMVJU9
Page 17: ...SiUS041829E Part 2 Specifications 13 1 Specifications 14 Part 2 Specifications ...
Page 125: ...SiUS041829E Check Part 6 Service Diagnosis 121 18 class R25105 1 2 3 4 Multimeter ...
Page 127: ...SiUS041829E Check Part 6 Service Diagnosis 123 18 class R20704 W V U DC_P1 DC_N1 ...
Page 143: ...SiUS041829E Operation Limit Part 8 Appendix 139 4 Operation Limit RX09 12 18RMVJU9 3D092209E ...