background image

RXH-C

Pair Application,

Inverter Controlled Unit

technical data 

Split

Sky Air

air 
conditioning 

systems

Summary of Contents for RXH20CVMB

Page 1: ...RXH C Pair Application Inverter Controlled Unit technical data Split Sky Air air conditioning systems...

Page 2: ...products and services and to assist in maintaining and improving the quality of the environment Daikin Europe N V is approved by LRQA for its Quality Management System in accordance with the ISO9001...

Page 3: ...sional drawings 7 5 Operation range 8 6 Piping diagrams 9 7 Wiring diagrams 10 8 Sound level 11 Sound level data Sound pressure spectrum 9 Accessories 13 Standard accessories Optional accessories 10 C...

Page 4: ...e mounted easily on a roof or terrace or simply placed against an outside wall They are fitted with a swing compressor renowned for its low noise and high energy efficiency Pair Application Inverter C...

Page 5: ...ally sealed swing type Model 1YC23NXD A Motor output 600 Oil type FVC50K Oil charge volume 0 375 PIPING CONNECTIONS liquid mm 6 4 gas mm 9 5 drain mm 18 0 INSULATION MATERIAL Heat insulation Both liqu...

Page 6: ...D044325 SYMBOLS MCA Min Circuit Amps A MFA Max Fuse Amps A RHz Rated operating frequency Hz RLA Rated Load Amps A OFM Outdoor Fan Motor IFM Indoor Fan Motor FLA Full Load Amps W Rated motor output W N...

Page 7: ...66 2 08 1 76 0 67 2 02 1 72 0 68 1 94 1 65 0 74 18 0 25 2 43 2 06 0 54 2 35 2 00 0 61 2 27 1 93 0 67 2 23 1 89 0 68 2 17 1 85 0 69 2 08 1 77 0 75 19 0 27 2 52 2 14 0 55 2 43 2 06 0 61 2 35 1 99 0 67 2...

Page 8: ...87 3 03 0 94 3 62 1 02 4 01 1 07 20 0 2 03 0 84 2 52 0 91 3 01 0 98 3 60 1 06 3 99 1 11 21 0 2 02 0 86 2 51 0 93 3 00 0 99 3 59 1 07 3 98 1 13 22 0 2 01 0 88 2 50 0 95 2 99 1 01 3 58 1 09 3 98 1 15 2...

Page 9: ...hose for connection 4 x holes for anchor bolts M8 or M10 Name plate Terminal strip with earth terminal Wiring inlet Gas stop valve J B CuT Liquid stop valve J A CuT Service port Outdoor air thermistor...

Page 10: ...WB Notes The graph is based on the following conditions 1 Equivalent piping length 7 5 m 2 Level difference 0 m 3 Air flow rate high Indoor temp CDB 10 CDB Outdoor temp CWB Cooling Heating Pair Applic...

Page 11: ...s stop valve Muffler with filter Muffler with filter Muffler 3D042769A RXH35C Outdoor temperature thermistor Heat exchanger Propeller fan Liquid stop valve Field piping Field piping Accumulator Compre...

Page 12: ...d circuit board MRCW MRL MRM10 MRM20 Magnetic relay N Neutral Q1L Overload protector R1T R2T R3T Thermistor S20 S75 S80 S90 Connector SA1 Surge arrester Z1C Z2C Z3C Ferrite core IC11 Solid state relay...

Page 13: ...r level cooling heating 230V 50Hz Measuring location Cooling heating H L RXH20C 46 47 61 62 RXH25C 46 47 61 62 RXH35C 48 48 63 63 This information was not available at the time of publication Pair App...

Page 14: ...and sound pressure level Octave band sound pressure level approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 3D044291 3D044291 Octave band center fre...

Page 15: ...upplied with the outdoor unit 1 9 2 Optional accessories RXH C RXH20CVMB RXH25CVMB RXH35CVMB Air direction adjustment grille KPW937A4 Installation manual Pair Application Inverter Controlled Unit R 41...

Page 16: ...10 Center of gravity RXH20 25C 4D044156 RXH35C 4D044157 Pair Application Inverter Controlled Unit R 410A RXH20 25 35CVMB 1 10 14 Split Sky Air Outdoor Units...

Page 17: ...es for outdoor unit Adjust foot height until the unit is leveled Otherwise water leakage or pooling of water may occur Where there is a danger of the unit falling use foot bolts or wires Allow space f...